EP250905a
X-ray transient detected by Einstein Probe with no optical counterpart identified.
AI Summary
An X-ray transient (EP250905a) was detected by the Einstein Probe's Wide-field X-ray Telescope (WXT) and Follow-up X-ray Telescope (FXT), showing significant flux decay over time. Follow-up observations by various ground-based telescopes did not reveal any optical counterparts.
Key facts
| Event | EP250905a |
|---|---|
| Event ID | 01709201261 |
| Alert type | X-ray transient |
| Trigger time | 2025-09-05 11:11:49 UTC |
| Position (J2000) | RA 4.4504°, Dec +37.4697° ± 10.0″ (EP-FXT afterglow position, GCN 41737) |
| Redshift | 0.28 (tentative) (GCN 41732) |
| Net count rate | 0.08 |
| Image SNR | 12.3 |
| GCN notices | 1 |
| GCN circulars | 7 |
Every localisation reported in Circulars (3)
| Instrument | Of | Error | Circular |
|---|---|---|---|
| EP-WXT | burst | 3.0′ (90%) | GCN 41725 |
| EP-FXT | afterglow | 20.0″ (90%) | GCN 41725 |
| EP-FXT | afterglow | 10.0″ (90%) | GCN 41737 |
Observations (14)
Values parsed from the Circular text; each row names its Circular.
| Time since trigger | UTC | Band | As reported | Normalised | Exposure | Telescope | Instrument | Circular |
|---|---|---|---|---|---|---|---|---|
| T+7 min | 2025-09-05 11:18:34 | 0.5-10 keV | 4.5 1e-13 erg/s/cm^2 | 4.50e-13 erg/cm2/s | — | Einstein Probe | FXT | GCN 41737 |
| T+2.7 h | 2025-09-05 13:56:13 | Sloan i | 22.9 mag | 22.9 AB mag | 180 s | 100C telescope of the JinShan project | — | GCN 41732 |
| T+6.7 h | 2025-09-05 17:52:32 | C | > 17.2 mag (limit) | 17.2 Vega mag | 60 s | MASTER-Kislovodsk | — | GCN 41727 |
| T+6.8 h | 2025-09-05 18:02:22 | C | > 17.2 mag (limit) | 17.2 Vega mag | 60 s | MASTER-Kislovodsk | — | GCN 41727 |
| T+9.1 h | 2025-09-05 20:19:01 | r | > 23.2 AB mag (limit) | 23.2 AB mag | 52 s | — | — | GCN 41734 |
| T+9.1 h | 2025-09-05 20:19:01 | r | 22.14 ± 0.04 AB mag | 22.14 AB mag | 52 s | — | — | GCN 41734 |
| T+9.1 h | 2025-09-05 20:19:01 | i | > 23.1 AB mag (limit) | 23.1 AB mag | 52 s | — | — | GCN 41734 |
| T+9.1 h | 2025-09-05 20:19:01 | r | > 23.2 AB mag (limit) | 23.2 AB mag | 52 s | — | — | GCN 41734 |
| T+10.9 h | 2025-09-05 22:05:49 | i' | > 22.6 mag (limit) | 22.6 AB mag | — | Liverpool Telescope | IO:O optical camera | GCN 41742 |
| T+11.1 h | 2025-09-05 22:17:49 | SDSS r' | 22.6 ± 0.4 AB mag | 22.6 AB mag | 900 s | Liverpool Telescope | IO:O | GCN 41738 |
| T+11.1 h | 2025-09-05 22:17:49 | SDSS r' | > 22.5 AB mag (limit) | 22.5 AB mag | 900 s | Liverpool Telescope | IO:O | GCN 41738 |
| T+11.1 h | 2025-09-05 22:17:49 | SDSS g' | > 21.5 AB mag (limit) | 21.5 AB mag | 900 s | Liverpool Telescope | IO:O | GCN 41738 |
| — | — | 0.5-4 keV | 1.4 1e-9 erg/s/cm^2 | 1.40e-9 erg/cm2/s | — | Einstein Probe | WXT | GCN 41737 |
| — | — | 0.5-4 keV | 5.7 1e-10 erg/s/cm^2 | 5.70e-10 erg/cm2/s | — | Einstein Probe | WXT | GCN 41737 |
Notices (1)
Einstein Probe WXT — XRAY · Fri, 05 Sep 2025 11:11:49 GMT
GCN Circulars (7)
GCN-41742 — EP250905a
· Sat, 06 Sep 2025 21:23:03 GMT
The Liverpool Telescope team at Liverpool John Moores University reported no detection of the optical counterpart of fast X-ray transient EP250905a in i-band observations using the IO:O optical camera. The team obtained six 100-second exposures starting approximately 11 hours after the trigger and reached a 3-sigma limiting magnitude of i > 22.6 mag.
GCN-41738 — EP250905a
· Sat, 06 Sep 2025 13:20:01 GMT
Astronomers using the 2m Liverpool Telescope reported no new sources or significant variability in the optical band for EP250905a, 11.1 hours after an X-ray detection. They measured upper limits of r' > 22.5 and g' > 21.5 for the source.
GCN-41737 — EP250905a
· Sat, 06 Sep 2025 11:24:15 GMT
The Einstein Probe mission detected an X-ray transient, EP250905a, with the Wide-field X-ray Telescope (WXT) and the Follow-up X-ray Telescope (FXT). The transient was initially detected by WXT with a peak flux of 1.4 x 10^(-9) erg/s/cm^2 and an average unabsorbed flux of 5.7 x 10^(-10) erg/s/cm^2. FXT observed the source 405 seconds later and detected a fading source with an average unabsorbed flux of 4.5 x 10^(-13) erg/s/cm^2. Both telescopes found similar Galactic hydrogen column densities and photon indices.
GCN-41734 — EP250905a
· Sat, 06 Sep 2025 02:50:51 GMT
Astronomers observed the localization of the x-ray flare EP250905a and detected five potential new sources within the error circle, including one optical and multiple NIR counterparts. Follow-up observations are encouraged to determine the variable nature of these sources.
GCN-41732 — EP250905a
· Sat, 06 Sep 2025 01:19:57 GMT
A new optical source with a magnitude of 22.9 has been detected in the Sloan i-band, likely corresponding to the counterpart of the event EP250905a, which was initially detected by the Einstein Probe. This source is located within a known GLADE galaxy with a redshift of approximately 0.28.
GCN-41727 — EP250905a
· Fri, 05 Sep 2025 18:09:28 GMT
The MASTER-Kislovodsk robotic telescope in Russia observed the transient EP250905a, located at galactic coordinates (-25, 116), reaching an upper limit of 17.2 mag in clear band filters. The observations began 18309 seconds after notice time and 24012 seconds after trigger time.
GCN-41725 — EP250905a
· Fri, 05 Sep 2025 12:44:26 GMT
The Einstein Probe mission, a space X-ray observatory, has detected an X-ray transient designated EP250905a using its Wide-field X-ray Telescope (WXT). The transient triggered the WXT at RA = 4.441 deg, DEC = 37.493 deg (J2000), with an uncertainty of 3 arcmin. A follow-up observation with the Follow-up X-ray Telescope (FXT) identified an uncatalogued X-ray source at RA = 4.4517 deg, DEC = 37.4728 deg (J2000), with an uncertainty of 20 arcsec. The Einstein Probe was launched in 2024 and is designed to monitor the soft X-ray sky with X-ray follow-up capability.