EP260110a
X-ray transient detected with no optical counterparts
AI Summary
An X-ray transient event, EP260110a, was detected by the Einstein Probe WXT. Follow-up observations using various telescopes including GTC and NOT did not reveal any new optical counterparts within the error circle, suggesting a brief or highly energetic emission source.
Key facts
| Event | EP260110a |
|---|---|
| Event ID | 01709251242 |
| Alert type | X-ray transient |
| Trigger time | 2026-01-10 11:58:23 UTC |
| Position (J2000) | RA 199.4321°, Dec +65.8490° ± 10.0″ (EP-FXT afterglow position, GCN 43367) |
| T90 | 85 s (WXT, GCN 43367) |
| Net count rate | 0.09 |
| Image SNR | 7.5 |
| GCN notices | 1 |
| GCN circulars | 11 |
Every localisation reported in Circulars (3)
| Instrument | Of | Error | Circular |
|---|---|---|---|
| EP-WXT | burst | 3.0′ (90%) | GCN 43363 |
| EP-FXT | afterglow | 20.0″ (90%) | GCN 43363 |
| EP-FXT | afterglow | 10.0″ (90%) | GCN 43367 |
Burst properties (1)
From burst catalogues and as each instrument's Circular reported them; Circular values parsed from the text.
| Property | Value | Band | Instrument | Spectral model | Source |
|---|---|---|---|---|---|
| Duration | 85 s | — | WXT | — | GCN 43367 |
Observations (21)
Values parsed from the Circular text; each row names its Circular.
| Time since trigger | UTC | Band | As reported | Normalised | Exposure | Telescope | Instrument | Circular |
|---|---|---|---|---|---|---|---|---|
| T+4 min | 2026-01-10 12:02:17 | 0.5-10 keV | 1.52 1e-12 erg/s/cm^2 | 1.52e-12 erg/cm2/s | 4576 s | EP-FXT | FXT | GCN 43367 |
| T+18 min | 2026-01-10 12:16:23 | r | > 22.8 AB mag (limit) | 22.8 AB mag | 3000 s | COLIBRÍ | DDRAGO | GCN 43366 |
| T+18 min | 2026-01-10 12:16:23 | z | > 21.8 AB mag (limit) | 21.8 AB mag | 3000 s | COLIBRÍ | DDRAGO | GCN 43366 |
| T+20 min | 2026-01-10 12:18:23 | — | > 17.3 mag (limit) | — | — | BOOTES-5/JGU | — | GCN 43364 |
| T+23 min | 2026-01-10 12:20:57 | i | > 18.6 AB mag (limit) | 18.6 AB mag | 60 s | SVOM/C-GFT | LATIOS | GCN 43365 |
| T+4.1 h | 2026-01-10 16:04:59 | VT_B | > 23.5 AB mag (limit) | 23.5 AB mag | 3640 s | SVOM | VT | GCN 43375 |
| T+4.6 h | 2026-01-10 16:36:47 | VT_R | > 23.5 AB mag (limit) | 23.5 AB mag | 3500 s | SVOM | VT | GCN 43375 |
| T+13.8 h | 2026-01-11 01:46:23 | r | > 23.5 AB mag (limit) | 23.5 AB mag | 900 s | NOT | ALFOSC | GCN 43391 |
| T+14.1 h | 2026-01-11 02:04:23 | z | > 22.3 AB mag (limit) | 22.3 AB mag | 1000 s | NOT | ALFOSC | GCN 43391 |
| T+19.0 h | 2026-01-11 06:59:35 | H | > 23.3 AB mag (limit) | 23.3 AB mag | 1280 s | GTC | EMIR | GCN 43391 |
| T+31.1 h | 2026-01-11 19:01:43 | C | > 16.4 mag (limit) | 16.4 Vega mag | 180 s | MASTER-Kislovodsk | — | GCN 43372 |
| T+31.1 h | 2026-01-11 19:01:43 | C | > 17.6 mag (limit) | 17.6 Vega mag | 180 s | MASTER-Kislovodsk | — | GCN 43372 |
| T+39.1 h | 2026-01-12 03:03:11 | r | > 24.2 AB mag (limit) | 24.2 AB mag | 900 s | NOT | ALFOSC | GCN 43391 |
| T+39.4 h | 2026-01-12 03:21:11 | z | > 22.7 AB mag (limit) | 22.7 AB mag | 1000 s | NOT | ALFOSC | GCN 43391 |
| T+21.8 d | 2026-02-01 06:12:47 | H | > 23.3 AB mag (limit) | 23.3 AB mag | 1280 s | GTC | EMIR | GCN 43615 |
| — | — | R | > 19.6 Vega mag (limit) | 19.6 Vega mag | — | 0.7-m telescope of the Thai Robotic Telescope network (TRT) | — | GCN 43390 |
| — | — | R | > 20.9 Vega mag (limit) | 20.9 Vega mag | — | 0.7-m telescope of the Thai Robotic Telescope network (TRT) | — | GCN 43390 |
| — | — | R | > 21 Vega mag (limit) | 21 Vega mag | — | 0.7-m telescope of the Thai Robotic Telescope network (TRT) | — | GCN 43390 |
| — | — | R | > 21 Vega mag (limit) | 21 Vega mag | — | Katzman Automatic Imaging Telescope (KAIT) | located at Lick Observatory | GCN 43368 |
| — | — | 0.5-10 keV | 1.15 1e-13 erg/s/cm^2 | 1.15e-13 erg/cm2/s | 3032 s | EP-FXT | FXT | GCN 43367 |
| — | — | clear | > 20.1 mag (limit) | 20.1 Vega mag | 720 s | BOOTES-5/JGU | — | GCN 43364 |
Notices (1)
Einstein Probe WXT — XRAY · Sat, 10 Jan 2026 11:58:23 GMT
GCN Circulars (11)
GCN-43615 — EP260110a
· Wed, 04 Feb 2026 20:43:55 GMT
Astronomers using the Gran Telescopio Canarias (GTC) with the Espectrógrafo Multiobjeto Infra-Rojo (EMIR) observed the field of fast X-ray transient EP260110a 21.76 days after the trigger. No new sources were detected within the error circle down to a limiting magnitude of H > 23.3.
GCN-43391 — EP260110a
· Tue, 13 Jan 2026 16:52:27 GMT
A team of astronomers led by G. Corcoran from University College Dublin observed the X-ray transient EP260110a using the Nordic Optical Telescope (NOT) and Gran Telescopio Canarias (GTC). They obtained upper limits in r, z, and H bands, which are consistent with previous observations. No new sources were detected within the uncertainty region of the transient. The team also noted the presence of two faint sources in both r- and H-band images, which require further investigation.
GCN-43390 — EP260110a
· Tue, 13 Jan 2026 16:28:35 GMT
Observations of the field EP260110a, detected by the Einstein Probe, using the 0.7-m Thai Robotic Telescope (TRT) did not detect any new sources within the error region, consistent with other non-detections. The 5-sigma upper limits in the R filter were reported as >19.6, >20.9, and >21.0 magnitudes at different times.
GCN-43375 — EP260110a
· Mon, 12 Jan 2026 04:40:42 GMT
The SVOM/VT team reported non-detection of a new uncatalogued source, EP260110a, in optical bands during a ToO observation using the Space Variable Objects Monitor (SVOM). The observation started 2.52 hours post-trigger and did not detect any new source within the error box. The 3 sigma limits in AB magnitude were derived as >23.5 for both VT_B and VT_R channels.
GCN-43372 — EP260110a
· Sun, 11 Jan 2026 19:09:24 GMT
The MASTER-Kislovodsk robotic telescope in Russia observed the EP260110a event 1-2 days after the trigger time, obtaining upper limits of 16.4 and 17.6 magnitudes in clear filter for two different observations. The event occurred near the galactic coordinates (51 deg. latitude, 118 deg. longitude) and was observed when the sun altitude was -54.1 degrees and zenith distance was 62 degrees.
GCN-43368 — EP260110a
· Sun, 11 Jan 2026 06:29:36 GMT
The KAIT team at UC Berkeley and NAOC reported no detection of a new source in the error circle of the gamma-ray burst EP260110a, using the Katzman Automatic Imaging Telescope at Lick Observatory. The team obtained images with exposure times of 20s, 40s, and 60s, and did not detect any source down to a limiting magnitude of 21.0 mag (Vega) at 1 hour after the burst. Their result is consistent with previous upper limits reported by other groups.
GCN-43367 — EP260110a
· Sun, 11 Jan 2026 04:43:42 GMT
Astronomical alert: EP260110a: refined analysis of the EP-WXT and EP-FXT observations
GCN-43366 — EP 260110a
· Sat, 10 Jan 2026 17:31:28 GMT
A team of astronomers led by Sarah Antier imaged the field of EP 260110a using the DDRAGO imager on the COLIBRÍ telescope. They observed for 50 minutes in the r and z filters and did not detect any new source within the error box of the previous alert down to a 5-sigma limit of r > 22.8 and z > 21.8. These upper limits are consistent with previous reports.
GCN-43365 — EP260110a
· Sat, 10 Jan 2026 14:51:46 GMT
The SVOM/C-GFT team reported no detection of a transient source in the error box provided by EP/WXT in i-band observations using the LATIOS instrument. The three-sigma upper limit was measured to be AB mag 18.6.
GCN-43364 — EP260110a
· Sat, 10 Jan 2026 13:26:38 GMT
A team of astronomers led by I. Perez-Garcia reported an optical upper limit observation of EP260110a using the BOOTES-5/JGU robotic telescope at San Pedro Martir Observatory. No detection was made down to magnitudes 17.3 and 20.1 in the first and coadd images, respectively.
GCN-43363 — EP260110a
· Sat, 10 Jan 2026 12:53:09 GMT
The Einstein Probe mission, a space X-ray observatory, has detected an X-ray transient designated EP260110a using its Wide-field X-ray Telescope (WXT). The transient's position was determined to be R.A. = 199.406 deg, DEC = 65.845 deg (J2000) with an uncertainty of 3 arcmin. A follow-up observation with the Follow-up X-ray Telescope (FXT) identified an uncatalogued X-ray source at R.A. = 199.4371 deg, DEC = 65.8476 deg (J2000) with an uncertainty of 20 arcsec. Further information will be provided once telemetry data is received.
AI summary generated Sat, 14 Nov 2026 11:03:57 GMT.