An X-ray transient (EP261007b) was detected by the Einstein Probe WXT and followed up with various instruments.
AI Summary
The initial detection of EP261007b showed a net count rate of 0.04 counts/s, and follow-up observations with FXT and other telescopes suggested fading X-ray emission and no associated optical counterpart.
Measurements
| Event | EP261007b |
|---|---|
| Event ID | 01709321008 |
| Source | Einstein Probe WXT |
| Alert type | XRAY |
| Significance | medium |
| Trigger time (UTC) | Wed, 07 Oct 2026 15:05:16 GMT |
| Right ascension (J2000) | 356.3481° |
| Declination (J2000) | 11.3539° |
| Position error radius | 0.005555555555555556° (20.0″) |
| Position from | EP-FXT afterglow position, GCN 45847 |
| Net count rate | 0.04 |
| Image SNR | 7.6 |
| GCN notices | 1 |
| GCN circulars | 12 |
Every localisation reported in Circulars (2)
| Instrument | Of | Error | Circular |
|---|---|---|---|
| EP-WXT | burst | 3.0′ (90%) | GCN 45847 |
| EP-FXT | afterglow | 20.0″ (90%) | GCN 45847 |
Observations (21)
Values parsed from the Circular text; each row names its Circular.
| Time since trigger | Band | Value | Telescope | Circular |
|---|---|---|---|---|
| T+16 s | 4-120 keV | < 1.20e-8 erg/cm2/s (limit) | SVOM | GCN 45876 |
| T+16 s | 4-120 keV | < 1.10e-8 erg/cm2/s (limit) | SVOM | GCN 45876 |
| T+28 min | g | > 20.66 mag (limit) | 0.8-m telescope | GCN 45860 |
| T+28 min | clear | > 22.21 mag (limit) | 2.16-m telescope | GCN 45860 |
| T+35 min | i | > 20.4 AB mag (limit) | SVOM/C-GFT | GCN 45862 |
| T+74 min | VT_B | > 23.3 AB mag (limit) | SVOM/VT | GCN 45849 |
| T+74 min | VT_R | > 23 AB mag (limit) | SVOM/VT | GCN 45849 |
| T+74 min | VT_B | 21.9 ± 0.2 AB mag | SVOM/VT | GCN 45870 |
| T+74 min | VT_R | 21.6 ± 0.2 AB mag | SVOM/VT | GCN 45870 |
| T+118 min | g | > 21.4 AB mag (limit) | SVOM/C-GFT | GCN 45862 |
| T+2.0 h | r | > 20.9 AB mag (limit) | SVOM/C-GFT | GCN 45862 |
| T+10.9 h | r | > 23.8 AB mag (limit) | Nordic Optical Telescope | GCN 45864 |
| T+11.6 h | J | > 19.6 AB mag (limit) | Palomar 1-m | GCN 45861 |
| T+26.1 h | J | > 20 Vega mag (limit) | SYSU 80cm infrared telescope | GCN 45873 |
| T+39.0 h | C | > 19.4 mag (limit) | MASTER-SAAO | GCN 45908 |
| T+39.0 h | C | > 19.1 mag (limit) | MASTER-SAAO | GCN 45908 |
| T+39.0 h | C | > 19.1 mag (limit) | MASTER-SAAO | GCN 45908 |
| T+39.0 h | C | > 19.3 mag (limit) | MASTER-SAAO | GCN 45908 |
| T+3.0 d | 0.5–10 keV | < 2.30e-13 erg/cm2/s (limit) | Einstein Probe (EP) | GCN 45902 |
| — | 0.5–10 keV | 6.27e-14 erg/cm2/s | Einstein Probe (EP) | GCN 45902 |
| — | 0.5–4 keV | 7.9 ± 2.8 erg/cm2/s | EP-WXT | GCN 45872 |
Notices (1)
Einstein Probe WXT — XRAY · Wed, 07 Oct 2026 15:05:16 GMT
GCN Circulars (12)
GCN-45908 — EP261007b
· Sun, 11 Oct 2026 19:45:26 GMT
The MASTER-SAAO robotic telescope in South Africa observed the error box of EP261007b, providing upper magnitude limits of up to 19.4 mag, with observations beginning 13291 seconds after notice time and 1 days 53720 seconds after trigger time. The observations were conducted at a zenith distance of 47 degrees and a sun altitude of -34.6 degrees, with the galactic latitude and longitude being -48 and 99 degrees, respectively.
GCN-45902 — EP261007b
· Sun, 11 Oct 2026 15:56:45 GMT
The Einstein Probe (EP) detected an X-ray transient, EP261007b, which has since faded. A second follow-up observation revealed a possible X-ray counterpart to an optical transient, suggesting a potential association between the two, though further observations are needed for confirmation.
GCN-45876 — EP261007b
· Fri, 09 Oct 2026 14:43:57 GMT
The SVOM/ECLAIRs instrument conducted a targeted search for the X-ray transient EP261007b but did not detect any significant signal. The derived upper limit for the flux in the 4-120 keV energy band is 1.2e-8 erg/cm^2/s, which is significantly higher than the flux measured by EP-WXT in the 0.5-4 keV range.
GCN-45873 — EP261007b
· Fri, 09 Oct 2026 12:29:35 GMT
The SYSU 80cm infrared telescope observed the field of the X-ray transient EP261007b and did not detect any new source within the expected localization, setting a 5-sigma upper limit of J ~ 20.0 mag (Vega). This non-detection is consistent with previous reports, indicating the absence of a detectable optical counterpart.
GCN-45872 — EP261007b
· Fri, 09 Oct 2026 11:18:00 GMT
The X-ray transient EP261007b was detected by the Einstein Probe mission, triggering follow-up observations that identified two potential X-ray sources within the error region. The spectral analysis of these sources provided insights into their photon indices and unabsorbed fluxes, with no X-ray source detected at the position of a previously reported variable source.
GCN-45870 — EP261007b
· Fri, 09 Oct 2026 02:31:07 GMT
The SVOM/VT team reported the optical detection of a transient event, EP261007b, initially observed by the NOT. The event was detected in both VT_B and VT_R bands with magnitudes of 21.9+/-0.2 mag and 21.6+/-0.2 mag, respectively, using stacked images.
GCN-45864 — EP261007b
· Thu, 08 Oct 2026 15:56:21 GMT
Optical observations of the X-ray transient EP261007b using the Nordic Optical Telescope did not detect any source within the expected region, but a variable source was found 51 arcseconds away. The association between this new source and EP261007b is uncertain, and further monitoring is encouraged.
GCN-45862 — EP261007b
· Thu, 08 Oct 2026 15:08:18 GMT
The SVOM/C-GFT team reported optical upper limits for the field of EP261007b, detected by EP/WXT, using LATIOS. No credible candidate was detected in g, r, and i bands within the error box provided by EP/FXT, with upper limits of g > 21.4 AB, r > 20.9 AB, and i > 20.4 AB.
GCN-45861 — EP261007b
· Thu, 08 Oct 2026 13:48:40 GMT
A team of astronomers used the Palomar 1-m telescope with the WINTER camera to observe the field of EP261007b in the J-band, but did not detect any new source, setting a 5-sigma upper limit of J = 19.6 mag (AB). This observation was part of a broader effort to study transient events in the near-infrared spectrum.
GCN-45860 — EP261007b
· Thu, 08 Oct 2026 13:46:42 GMT
The Xinglong Observatory at NAOC reported on observations following the detection of EP261007b by EP-WXT. Using 0.8-m and 2.16-m telescopes, they obtained g-band and clear-band images but did not detect any optical counterpart candidate, with limiting magnitudes of 20.66 and 22.21 respectively, 0.46 hours after the trigger.
GCN-45849 — EP261007b
· Thu, 08 Oct 2026 06:45:49 GMT
The SVOM/VT telescope observed the field of EP261007b, detected by EP/WXT, but found no new optical sources within the error box provided by EP/FXT. The 3-sigma upper limits for the non-detection were measured at >23.3 mag in the VT_B band and >23.0 mag in the VT_R band.
GCN-45847 — EP261007b
· Thu, 08 Oct 2026 03:02:37 GMT
The Einstein Probe (EP) mission detected an X-ray transient, designated EP261007b, on October 7, 2026. The event was initially observed by the Wide-field X-ray Telescope (WXT) and subsequently confirmed by the Follow-up X-ray Telescope (FXT), with a refined position provided.