EP240625a
EP240625a, a X-ray transient, reported in 4 GCN Circulars. Best position RA 310.7308°, Dec -15.9760° (±10.0″) from the EP-FXT afterglow position, GCN 36760. 10 measured values from follow-up observations.
Key facts
| Event | EP240625a |
|---|---|
| Event ID | ep240625a |
| Alert type | X-ray transient |
| Trigger time | not reported |
| Position (J2000) | RA 310.7308°, Dec -15.9760° ± 10.0″ (EP-FXT afterglow position, GCN 36760) |
| T90 | 300 s (WXT, GCN 36757) |
| Peak flux | 1.30e-9 erg/s/cm^2 (0.5-4 keV, WXT, GCN 36757) |
| GCN notices | 0 |
| GCN circulars | 4 |
Every localisation reported in Circulars (2)
| Instrument | Of | Error | Circular |
|---|---|---|---|
| EP-WXT | burst | 2.0′ (90%) | GCN 36757 |
| EP-FXT | afterglow | 10.0″ (90%) | GCN 36760 |
Burst properties (3)
From burst catalogues and as each instrument's Circular reported them; Circular values parsed from the text.
| Property | Value | Band | Instrument | Spectral model | Source |
|---|---|---|---|---|---|
| Duration | 300 s | — | WXT | — | GCN 36757 |
| Peak flux | 1.3 1e-9 erg/s/cm^2 | 0.5-4 keV | WXT | — | GCN 36757 |
| Photon index | 1.8 ± 0.3 | 0.5-4 keV | WXT | power_law | GCN 36757 |
Observations (10)
Values parsed from the Circular text; each row names its Circular.
| Time since trigger | UTC | Band | As reported | Normalised | Exposure | Telescope | Instrument | Circular |
|---|---|---|---|---|---|---|---|---|
| T+91 min | — | z | 20.7 ± 0.2 mag | 20.7 AB mag | — | NOT | ALFOSC | GCN 36761 |
| — | — | L | > 20.04 AB mag (limit) | 20.04 AB mag | — | FRAM-CTA-N | KNC-ASO | GCN 36771 |
| — | — | G | > 19.84 AB mag (limit) | 19.84 AB mag | — | FRAM-CTA-N | KNC-ASO | GCN 36771 |
| — | — | R | > 19.46 AB mag (limit) | 19.46 AB mag | — | FRAM-CTA-N | KNC-ASO | GCN 36771 |
| — | — | B | > 20.13 AB mag (limit) | 20.13 AB mag | — | FRAM-CTA-N | KNC-ASO | GCN 36771 |
| — | — | R | > 16.95 AB mag (limit) | 16.95 AB mag | — | FRAM-CTA-N | FRAM-CTA-N | GCN 36771 |
| — | — | V | > 19.88 AB mag (limit) | 19.88 AB mag | — | FRAM-CTA-N | KNC-T32 | GCN 36771 |
| — | — | V | > 20.7 Vega mag (limit) | 20.7 Vega mag | — | FRAM-CTA-N | KNC-T32 | GCN 36771 |
| — | — | 0.5-10 keV | 1.7 ± 0.4 | — | 5780 s | Einstein Probe | FXT | GCN 36760 |
| — | — | 0.5-10 keV | 1.4 1e-13 erg/s/cm^2 | 1.40e-13 erg/cm2/s | 5780 s | Einstein Probe | FXT | GCN 36760 |
GCN Circulars (4)
GCN-36771 — EP240625a
· Thu, 27 Jun 2024 09:44:18 GMT
The GRANDMA collaboration, using telescopes including FRAM-CTA-N, KNC-T32, and KNC-ASO, conducted observations of the X-ray transient EP240625a detected by the Einstein Probe. No new optical counterpart was found within a 10 arcsec radius of the source, with upper limits on the magnitude provided for various filters.
GCN-36761 — EP240625a
· Tue, 25 Jun 2024 16:25:42 GMT
A faint optical transient was marginally detected within the error circle of the event EP240625a using the Nordic Optical Telescope, but its significance is uncertain due to low signal-to-noise ratio. Further observations are planned to confirm its nature.
GCN-36760 — EP240625a
· Tue, 25 Jun 2024 16:02:06 GMT
The Einstein Probe's Follow-up X-ray Telescope (FXT) detected a slowly fading X-ray source, EP240625a, approximately one hour after its initial detection. The source, located at R.A. = 310.7308 deg, DEC = -15.9760 deg, has an unabsorbed flux of 1.4 x 10^-13 erg/s/cm^2 in the 0.5-10 keV range, and no cataloged X-ray source is within the error circle, suggesting a new transient event.
GCN-36757 — EP240625a
· Tue, 25 Jun 2024 11:04:29 GMT
The Einstein Probe's Wide-field X-ray Telescope detected a fast X-ray transient, EP240625a, lasting approximately 300 seconds with a peak flux of ~1.3 x 10^-9 erg/s/cm^2. Follow-up observations are encouraged to determine the nature of this transient.
Rendered Mon, 16 Nov 2026 06:56:27 GMT.