Starithm STARITHM NovaTrace

EP240702a

EP240702a, a X-ray transient, reported in 5 GCN Circulars. Best position RA 328.2030°, Dec -38.9800° (±3.0′) from the EP-WXT position, GCN 36801. 7 measured values from follow-up observations.

Key facts

EventEP240702a
Event IDep240702a
Alert typeX-ray transient
Trigger timenot reported
Position (J2000)RA 328.2030°, Dec -38.9800° ± 3.0′ (EP-WXT position, GCN 36801)
T9050 s (WXT, GCN 36801)
Peak flux1.20e-8 erg/s/cm^2 (0.5-4 keV, WXT, GCN 36801)
GCN notices0
GCN circulars5

Every localisation reported in Circulars (1)

InstrumentOfErrorCircular
EP-WXTburst3.0′ (90%)GCN 36801

Burst properties (2)

From burst catalogues and as each instrument's Circular reported them; Circular values parsed from the text.

PropertyValueBandInstrumentSpectral modelSource
Duration50 s—WXT—GCN 36801
Peak flux1.2 1e-8 erg/s/cm^20.5-4 keVWXT—GCN 36801

Observations (7)

Values parsed from the Circular text; each row names its Circular.

Time since triggerUTCBandAs reportedNormalisedExposureTelescopeInstrumentCircular
T+37.2 h—R> 21.8 mag (limit)21.8 Vega mag—0.7-m telescope of the Thai Robotic Telescope (TRT) networkSpring Brook ObservatoryGCN 36831
T+37.2 h—I> 20.7 mag (limit)20.7 Vega mag—0.7-m telescope of the Thai Robotic Telescope (TRT) networkSpring Brook ObservatoryGCN 36831
——m400> 16.3 AB mag (limit)—300 s7DTmedium-band filterGCN 38725
——m875> 19.6 AB mag (limit)—300 s7DTmedium-band filterGCN 38725
——r> 20.2 AB mag (limit)20.2 AB mag300 s7DTmedium-band filterGCN 38725
——0.3-10 keV< 1.58 1e-13 erg/s/cm2 (limit)1.58e-13 erg/cm2/s1950 sSwiftXRTGCN 36808
——r> 21.5 mag (limit)21.5 AB mag—1-meter telescopeLas Cumbres Observatory node located at Cerro Tololo Inter-American Observatory in ChileGCN 36806

GCN Circulars (5)

GCN-38725 — EP240702a · Mon, 30 Dec 2024 16:17:28 GMT
A team of astronomers using the 7-Dimensional Telescope (7DT) searched for the optical counterpart of a fast X-ray transient, EP240702a, but did not detect any significant event. They observed the localization center provided by the Wide-field X-ray Telescope (WXT) on board the Einstein Probe (EP) mission in twenty medium-band filters, with 5-sigma upper limits ranging from 16.3 to 19.6 mag. Despite combining all images and increasing the depth, no detection was made. The 7DT aims to detect optical counterparts of gravitational wave sources and conduct the 7-Dimensional Sky Survey of the Southern Hemisphere.

GCN-36831 — EP240702a · Fri, 05 Jul 2024 15:23:17 GMT
A team of astronomers led by S. Tinyanont from the National Astronomical Research Institute of Thailand and National Astronomical Observatories, China, reported no detection of an optical transient in the field of EP240702a using the 0.7-m Thai Robotic Telescope (TRT) network. The observations were carried out 1.55 days after the initial trigger, with exposure times of 360 seconds in R- and I-bands. The 5-sigma limiting magnitudes were found to be R ~ 21.8 and I ~ 20.7.

GCN-36808 — EP240702a · Wed, 03 Jul 2024 13:31:10 GMT
The Einstein Probe team reported the detection of a fast X-ray transient, EP240702a, using the Wide-field X-ray Telescope (WXT). Following this detection, a Swift target of opportunity observation was conducted using Swift/XRT. No significant X-ray source was detected within the observation, resulting in a flux upper limit of 1.58 x 10^-13 ergs/cm^2/s in the 0.3-10 keV energy range at the 90% confidence level.

GCN-36806 — EP240702a · Wed, 03 Jul 2024 04:26:38 GMT
The Einstein Probe detected a fast X-ray transient, EP240702a, and observations in the r band using the 1-meter telescope at Cerro Tololo Inter-American Observatory did not detect a new optical source within the error box, limiting its magnitude to ~21.5.

GCN-36801 — EP240702a · Tue, 02 Jul 2024 09:10:43 GMT
A fast X-ray transient, EP240702a, was detected by the Wide-field X-ray Telescope (WXT) on board the Einstein Probe (EP) mission. The transient occurred on July 2, 2024, and its position was determined to be R.A. = 328.203 deg, DEC = -38.980 deg (J2000) with an uncertainty of 3 arcmin. The transient lasted for approximately 50 seconds and had a peak absorbed flux of ~1.2 x 10^-8 erg/s/cm^2 in the 0.5-4 keV band. The Einstein Probe team triggered a Swift observation and encouraged further follow-up to identify the nature of this transient.

View live event on Starithm

Rendered Mon, 16 Nov 2026 07:06:47 GMT.