EP240708a
EP240708a, a X-ray transient, reported in 9 GCN Circulars. Best position RA 345.9656°, Dec -22.8428° (±10.0″) from the Swift-XRT afterglow position, GCN 36840. 11 measured values from follow-up observations.
Key facts
| Event | EP240708a |
|---|---|
| Event ID | ep240708a |
| Alert type | X-ray transient |
| Trigger time | not reported |
| Position (J2000) | RA 345.9656°, Dec -22.8428° ± 10.0″ (Swift-XRT afterglow position, GCN 36840) |
| T90 | 1300 s (0.5-4 keV, on board the Einstein Probe (EP) mission, GCN 36838) |
| Peak flux | 1.10e-9 erg/s/cm^2 (0.5-4 keV, on board the Einstein Probe (EP) mission, GCN 36838) |
| GCN notices | 0 |
| GCN circulars | 9 |
Every localisation reported in Circulars (2)
| Instrument | Of | Error | Circular |
|---|---|---|---|
| EP-WXT | burst | 3.0′ (90%) | GCN 36838 |
| Swift-XRT | afterglow | 10.0″ (90%) | GCN 36840 |
Burst properties (3)
From burst catalogues and as each instrument's Circular reported them; Circular values parsed from the text.
| Property | Value | Band | Instrument | Spectral model | Source |
|---|---|---|---|---|---|
| Duration | 1300 s | 0.5-4 keV | on board the Einstein Probe (EP) mission | — | GCN 36838 |
| Peak flux | 1.1 1e-9 erg/s/cm^2 | 0.5-4 keV | on board the Einstein Probe (EP) mission | — | GCN 36838 |
| Photon index | 1.57 | 0.5-4 keV | on board the Einstein Probe (EP) mission | — | GCN 36838 |
Observations (11)
Values parsed from the Circular text; each row names its Circular.
| Time since trigger | UTC | Band | As reported | Normalised | Exposure | Telescope | Instrument | Circular |
|---|---|---|---|---|---|---|---|---|
| T+5.5 h | — | r | > 21 mag (limit) | 21 AB mag | — | 1-meter telescope | — | GCN 36852 |
| T+9.1 h | — | R | > 19.5 mag (limit) | 19.5 Vega mag | — | Katzman Automatic Imaging Telescope (KAIT) | 0.76-m telescope | GCN 36845 |
| T+9.1 h | — | R | > 20.5 mag (limit) | 20.5 Vega mag | — | Katzman Automatic Imaging Telescope (KAIT) | 0.76-m telescope | GCN 36845 |
| T+17.2 h | — | r | > 22.6 AB mag (limit) | 22.6 AB mag | 1800 s | LOT | — | GCN 36839 |
| T+17.8 h | — | g | > 22.4 AB mag (limit) | 22.4 AB mag | 1800 s | LOT | — | GCN 36839 |
| T+18.5 h | — | g | > 18.2 mag (limit) | 18.2 AB mag | 120 s | 1.2-meter-aperure telescope | C-GFT | GCN 36841 |
| T+18.5 h | — | r | > 18.9 mag (limit) | 18.9 AB mag | 120 s | 1.2-meter-aperure telescope | C-GFT | GCN 36841 |
| T+18.5 h | — | i | > 18.9 mag (limit) | 18.9 AB mag | 120 s | 1.2-meter-aperure telescope | C-GFT | GCN 36841 |
| — | — | r | > 24.1 mag (limit) | 24.1 AB mag | — | 2.56-m Nordic Optical Telescope (NOT) | ALFOSC | GCN 36842 |
| — | — | 0.5-10 keV | 2.37 1e-13 erg/s/cm^2 | 2.37e-13 erg/cm2/s | — | EP/FXT | Follow-up X-ray Telescope (FXT) | GCN 36840 |
| — | — | 0.3-10 keV | < 2.67 1e-13 erg/s/cm^2 (limit) | 2.67e-13 erg/cm2/s | — | Swift/XRT | XRT | GCN 36840 |
GCN Circulars (9)
GCN-37001 — EP240708a
· Thu, 01 Aug 2024 18:22:32 GMT
Duplicate GCN circular (37001) reports follow-up observations of a candidate counterpart by Amar Aryan at National Central University's Institute of Astronomy (NCUIA), but no specific astronomical event or measurement details are provided in the alert.
GCN-36888 — EP240708a
· Tue, 16 Jul 2024 15:09:00 GMT
A team of astronomers led by J. Quirola-Vásquez et al. reported the non-detection of an X-ray counterpart to the fast X-ray transient EP240708a using the Swift-XRT Observatory. The upper limit on the source count rate is 3.5E-3 cnt/s and the upper limit on the flux is 1.5E-13 erg cm-2 s-1.
GCN-36852 — EP240708a
· Fri, 12 Jul 2024 08:02:30 GMT
The Einstein Probe detected a fast X-ray transient, EP240708a, and observations in the r band using the 1-meter telescope at the Las Cumbres Observatory did not detect a new optical source within the error box, with a limiting magnitude of 21.0.
GCN-36845 — EP240708a
· Wed, 10 Jul 2024 19:14:53 GMT
The KAIT team at Lick Observatory conducted optical observations of the fast X-ray transient EP240708a using the 0.76-m Katzman Automatic Imaging Telescope. No new optical counterpart was detected within the error box, with limiting magnitudes of approximately 19.5 mag for a single image and 20.5 mag for co-added images.
GCN-36842 — EP240708a
· Wed, 10 Jul 2024 14:38:50 GMT
Astronomers using the 2.56-m Nordic Optical Telescope (NOT) did not detect an optical transient in the error circle of EP240708a, a gamma-ray burst detected by EP/WXT. They report a marginal detection of an uncatalogued source with r ~ 24.0 mag, ~21.7 arcsec away from the center and not present in archival data.
GCN-36841 — EP240708a
· Wed, 10 Jul 2024 14:15:39 GMT
A team of astronomers led by Chao Wu at NAOC observed the field of the fast X-ray transient EP240708a using the Chinese Ground Follow-up Telescope (C-GFT) in the SVOM mission. No optical afterglow was detected within the error box down to limiting magnitudes of 18.2, 18.9, and 18.9 for g, r, and i bands, respectively. This result is consistent with previous reports and indicates that no significant optical emission was detected from the transient.
GCN-36840 — EP240708a
· Wed, 10 Jul 2024 10:01:58 GMT
Astronomers detected a new fast X-ray transient, EP240708a, using the Einstein Probe mission's EP-WXT trigger. They observed it with the Follow-up X-ray Telescope (FXT) on board the Einstein Probe mission and Swift/XRT. The FXT observation revealed a faint X-ray source with a photon index of 1.62 and an unabsorbed flux of 2.37 x 10^-13 erg/s/cm^2. Swift/XRT did not detect a significant X-ray source within the 3 arcmin region around the WXT position, resulting in a flux upper limit of 2.67 x 10^-13 erg/s/cm^2.
GCN-36839 — EP240708a
· Tue, 09 Jul 2024 20:13:05 GMT
A team of astronomers led by Amar Aryan at National Central University used the One-meter Telescope at Lulin Observatory to search for an optical counterpart to the fast X-ray transient EP240708a. No evidence of a new source was found in the stacked and subtracted frames, and they report 3-sigma upper limits on magnitudes in the r and g bands of >22.6 and >22.4, respectively.
GCN-36838 — EP240708a
· Tue, 09 Jul 2024 12:19:35 GMT
A fast X-ray transient, EP240708a, was detected by the Wide-field X-ray Telescope (WXT) on board the Einstein Probe (EP) mission on July 8, 2024. The transient has a peak flux of ~1.1 x 10^-9 erg/s/cm^2 and a duration of approximately 1300 seconds. The source is located at R.A. = 345.963 deg, DEC = -22.840 deg (J2000) with an uncertainty of 3 arcmin. The transient cannot be identified with any known X-ray sources within the 3 arcmin region around the source position. The Einstein Probe team is proposing follow-up observations to identify the nature of this transient.