Starithm STARITHM NovaTrace

EP241126a

EP241126a, a X-ray transient, reported in 10 GCN Circulars. Best position RA 33.7444°, Dec +11.7013° (±10.0″) from the EP-FXT afterglow position, GCN 38339. 12 measured values from follow-up observations.

Key facts

EventEP241126a
Event IDep241126a
Alert typeX-ray transient
Trigger timenot reported
Position (J2000)RA 33.7444°, Dec +11.7013° ± 10.0″ (EP-FXT afterglow position, GCN 38339)
Peak flux2.00e-8 erg/s/cm^2 (0.5-4 keV, WXT, GCN 38335)
GCN notices0
GCN circulars10

Every localisation reported in Circulars (3)

InstrumentOfErrorCircular
EP-WXTburst2.4′ (90%)GCN 38335
EP-FXTafterglow20.0″ (90%)GCN 38335
EP-FXTafterglow10.0″ (90%)GCN 38339

Burst properties (2)

From burst catalogues and as each instrument's Circular reported them; Circular values parsed from the text.

PropertyValueBandInstrumentSpectral modelSource
Peak flux2.00e-8 erg/s/cm^20.5-4 keVWXT—GCN 38335
Photon index0.90.5-4 keVWXTpower_lawGCN 38335

Observations (12)

Values parsed from the Circular text; each row names its Circular.

Time since triggerUTCBandAs reportedNormalisedExposureTelescopeInstrumentCircular
T+6.8 h—R22 mag22 Vega mag3000 s0.7-m telescopeTRTGCN 38337
T+7.5 h—0.5-10 keV2.2—2980 sEinstein ProbeFXTGCN 38339
T+7.5 h—0.5-10 keV1.3 1e-13 erg/s/cm^21.30e-13 erg/cm2/s2980 sEinstein ProbeFXTGCN 38339
T+9.5 h—r22.2 ± 0.2 AB mag22.2 AB mag—1-meter telescopeSinistroGCN 38338
T+15.8 h—v> 22.2 mag (limit)22.2 Vega mag420 s1.6m Mephisto—GCN 38404
T+15.8 h—r> 22.3 mag (limit)22.3 AB mag420 s1.6m Mephisto—GCN 38404
T+16.2 h—r> 22.5 AB mag (limit)22.5 AB mag1800 sLOT—GCN 38344
T+24.4 h—SDSS r23.4 ± 0.3 AB mag23.4 AB mag2160 sNOTALFOSCGCN 38385
T+32.0 h—r23.325 ± 0.09 AB mag23.325 AB mag900 sSOARGoodman High Throughput SpectrographGCN 38409
T+33.3 h—VT_R22.95 ± 0.15 mag22.95 AB mag5670 sSVOMVTGCN 38378
T+33.3 h—VT_B> 24.1 mag (limit)24.1 AB mag5760 sSVOMVTGCN 38378
——r22.55 ± 0.23 AB mag22.55 AB mag480 sWFST—GCN 38357

GCN Circulars (10)

GCN-38409 — EP241126a · Mon, 02 Dec 2024 03:15:36 GMT
Astronomers at Swinburne University of Technology and UNC observed the optical counterpart of X-ray transient EP241126a using the SOAR telescope and measured a magnitude of 23.325 AB.

GCN-38404 — EP241126a · Sun, 01 Dec 2024 21:08:10 GMT
The Mephisto team at Yunnan University reported non-detection of the optical counterpart of fast X-ray transient EP241126a using the 1.6m Multi-channel Photometric Survey Telescope (Mephisto) in the v and r bands, 15.8 hours after the X-ray trigger. The team obtained 3-sigma upper limits of 22.2 mag in the v band and 22.3 mag in the r band.

GCN-38385 — EP241126a · Sat, 30 Nov 2024 03:53:22 GMT
A team of astronomers led by Daniele B. Malesani reported non-optical observations of the X-ray transient EP241126a using the Nordic Optical Telescope (NOT) equipped with the ALFOSC camera. The optical counterpart of the transient was marginally detected with a magnitude of r = 23.4 ± 0.3, 24.4 hours after the EP trigger. The observation was affected by poor seeing conditions.

GCN-38378 — EP241126a · Fri, 29 Nov 2024 09:11:17 GMT
The SVOM/VT team began observing the fast X-ray transient EP241126a approximately 30 hours after its burst in both VT_R and VT_B bands. The optical counterpart was detected in VT_R with a magnitude of 22.95 +/- 0.15 mag at 33.27 hours post-burst, but was not detected in VT_B with a 3 sigma limit of 24.1 mag. The Space Variable Objects Monitor (SVOM) is a China-France joint mission dedicated to observing gamma-ray bursts and other transient phenomena.

GCN-38357 — EP241126a · Thu, 28 Nov 2024 08:23:42 GMT
Astronomers using the Wide Field Survey Telescope (WFST) at Lenghu Astronomical Observation Base in China have detected the optical counterpart of the fast X-ray transient EP241126a, which was previously detected by multiple telescopes. The team obtained an initial magnitude measurement of 22.55 in the r band.

GCN-38344 — EP241126a · Wed, 27 Nov 2024 19:12:19 GMT
A team of astronomers led by Amar Aryan at National Central University reported non-detection of the optical counterpart of the fast X-ray transient EP241126a using the 1m LOT at the Lulin Observatory as part of the Kinder collaboration. The team did not detect the proposed optical counterpart, which seems to have faded beyond their detection limit. The team used the Python-based package AutoPhOT to perform PSF photometry and measured a 3-sigma upper limit of >22.5 mag in the AB system.

GCN-38339 — EP241126a · Wed, 27 Nov 2024 15:21:05 GMT
The Einstein Probe team reported the detection of a new X-ray source, EP241126a, using the Follow-up X-ray Telescope (FXT) on board the Einstein Probe. The source is located at RA = 33.7444 deg, DEC = 11.7013 deg and has an average unabsorbed flux of 1.3(+1.1/-0.5) x 10^(-13) erg/s/cm^2 in the 0.5-10 keV band. The FXT position is ~10 arcsec away from the likely optical counterpart. This detection follows the initial EP-WXT detection and marks the first X-ray observation by the Einstein Probe.

GCN-38338 — EP241126a · Wed, 27 Nov 2024 14:29:09 GMT
Astronomers using the 1-meter telescope at the Las Cumbres Observatory detected an optical counterpart of a fast X-ray transient, EP241126a, with a magnitude of 22.2. The observation was initiated about 9.5 hours after the X-ray detection by the Einstein Probe and was conducted as part of the Global Supernova Project.

GCN-38337 — EP241126a · Wed, 27 Nov 2024 14:09:43 GMT
Astronomers using the Thai Robotic Telescope (TRT) at Cerro Tololo Inter-American Observatory detected an uncatalogued optical source, likely the counterpart of the recently discovered X-ray transient EP241126a, located at R.A. (J2000) = 02:14:57.96, Dec. (J2000) = +11:42:04.76, with a magnitude of 22.0, 6.84 hours after the X-ray trigger.

GCN-38335 — EP241126a · Wed, 27 Nov 2024 09:18:24 GMT
The Einstein Probe mission has detected a fast X-ray transient, EP241126a, using its Wide-field X-ray Telescope (WXT). The transient, located at R.A. = 33.744 deg, DEC = 11.705 deg (J2000), has a peak flux of ~2 x 10^(-8) erg/s/cm^2 and lasted for over 60 seconds. The team has also performed a target of opportunity observation with the Follow-up X-ray Telescope (FXT) and identified an X-ray source within the error circle. No previously known bright X-ray sources were found in the vicinity, and further follow-up observations are encouraged to identify the nature of this transient.

View live event on Starithm

Rendered Mon, 16 Nov 2026 07:07:02 GMT.