Starithm STARITHM NovaTrace

EP250220a

EP250220a, a X-ray transient, reported in 9 GCN Circulars. Best position RA 113.4516°, Dec +39.8098° (±10.0″) from the EP-FXT afterglow position, GCN 39420. 14 measured values from follow-up observations.

Key facts

EventEP250220a
Event IDep250220a
Alert typeX-ray transient
Trigger timenot reported
Position (J2000)RA 113.4516°, Dec +39.8098° ± 10.0″ (EP-FXT afterglow position, GCN 39420)
T90150 s (WXT, GCN 39387)
GCN notices0
GCN circulars9

Every localisation reported in Circulars (2)

InstrumentOfErrorCircular
EP-WXTburst2.8′ (90%)GCN 39387
EP-FXTafterglow10.0″GCN 39420

Burst properties (2)

From burst catalogues and as each instrument's Circular reported them; Circular values parsed from the text.

PropertyValueBandInstrumentSpectral modelSource
Duration150 s—WXTpower_lawGCN 39387
Photon index1.80.5-4 keVWXTpower_lawGCN 39387

Observations (14)

Values parsed from the Circular text; each row names its Circular.

Time since triggerUTCBandAs reportedNormalisedExposureTelescopeInstrumentCircular
T+9.2 h—r> 22.65 AB mag (limit)22.65 AB mag1800 sLOT—GCN 39400
T+10.0 h—clear> 22.6 mag (limit)22.6 Vega mag3600 s2.16-m—GCN 39393
T+10.9 h—u> 22.85 AB mag (limit)22.85 AB mag900 s1.6m MephistoMulti-channel Photometric Survey TelescopeGCN 39402
T+10.9 h—v> 22.85 AB mag (limit)22.85 AB mag900 s1.6m MephistoMulti-channel Photometric Survey TelescopeGCN 39402
T+10.9 h—g> 23.1 AB mag (limit)23.1 AB mag900 s1.6m MephistoMulti-channel Photometric Survey TelescopeGCN 39402
T+10.9 h—r> 23.04 AB mag (limit)23.04 AB mag900 s1.6m MephistoMulti-channel Photometric Survey TelescopeGCN 39402
T+13.7 h—C> 12.9 mag (limit)12.9 Vega mag60 sMASTER-Tunka—GCN 39388
T+19.5 h—SDSS r'> 21.7 mag (limit)21.7 AB mag—Liverpool TelescopeIO:O optical cameraGCN 39408
T+19.5 h—SDSS i'> 21.8 mag (limit)21.8 AB mag—Liverpool TelescopeIO:O optical cameraGCN 39408
T+20.0 h—SDSS g'> 21.5 AB mag (limit)21.5 AB mag400 sLiverpool TelescopeIO:OGCN 39401
T+20.0 h—SDSS r'> 21.8 AB mag (limit)21.8 AB mag600 sLiverpool TelescopeIO:OGCN 39401
T+20.2 h—r> 25 AB mag (limit)25 AB mag59 sFraunhofer Telescope at Wendelstein Observatory (FTW)Three Channel Imager (3KK)GCN 39421
T+32.0 h—0.5-10 keV< 1.90e-14 erg/s/cm^2 (limit)1.90e-14 erg/cm2/s7000 sEinstein ProbeFXTGCN 39420
T+42.7 h—r> 24.4 AB mag (limit)24.4 AB mag59 sFraunhofer Telescope at Wendelstein Observatory (FTW)Three Channel Imager (3KK)GCN 39421

GCN Circulars (9)

GCN-39421 — EP250220a · Sat, 22 Feb 2025 16:33:18 GMT
A team of astronomers led by Malte Busmann at Ludwig-Maximilians-Universität München and Carnegie Mellon U. reported non-detections of a new or evolving source in the 90% localization area of EP250220a using the Three Channel Imager at the Fraunhofer Telescope at Wendelstein Observatory. They performed difference imaging in the r and i bands and found no significant change in brightness since the initial trigger. Their measurements are consistent with previous non-detections by other teams.

GCN-39420 — EP250220a · Sat, 22 Feb 2025 13:41:55 GMT
The Einstein Probe team reported two follow-up observations of the fast X-ray transient EP250220a using the Follow-up X-ray Telescope (FXT) on board the Einstein Probe (EP) mission. In the first observation, a faint X-ray source was detected, while no source was detected in the second observation. The team derived an upper limit for the non-detection.

GCN-39408 — EP250220a · Fri, 21 Feb 2025 20:23:53 GMT
The Liverpool Telescope team at Liverpool John Moores University reported no detection of a new object at the location of the fast X-ray transient EP250220a, using the IO:O optical camera. The team obtained six 90-second exposures in the SDSS r’ and i’ filters, 19.5 hours after the trigger. The non-detection is consistent with previous observations by other teams, and the limiting magnitudes are r > 21.7 mag and i > 21.8 mag.

GCN-39402 — EP250220a · Fri, 21 Feb 2025 15:06:39 GMT
The Mephisto team at Yunnan University observed the field of EP250220a using their 1.6m Multi-channel Photometric Survey Telescope (Mephisto) following a previous alert. No uncatalogued source was detected in their stacked images, and they report 3-sigma upper limits in uvgr bands. The first light in all three channels was achieved in December 2023.

GCN-39401 — EP250220a · Fri, 21 Feb 2025 15:01:44 GMT
The University of Leicester team used the 2m Liverpool Telescope to search for optical counterparts to the X-ray transient EP250220a but found no new sources within the error region. They report 3-sigma upper limits of g' > 21.5 and r' > 21.8.

GCN-39400 — EP250220a · Fri, 21 Feb 2025 14:16:24 GMT
A team of astronomers led by L. L. Fan from National Central University observed the field of the fast X-ray transient EP250220a using the 1m LOT at Lulin Observatory as part of the Kinder collaboration. They did not find any evidence of a new optical counterpart within the error circle of the EP-WXT localization or in the difference image using template subtraction. The team reported a 3-sigma upper limit of r-band magnitude > 22.65 for the transient, consistent with non-detection reported by Zhang et al.

GCN-39393 — EP250220a · Fri, 21 Feb 2025 07:51:20 GMT
The Xinglong Observatory at NAOC reported no detection of an optical transient associated with EP250220a, a gamma-ray burst detected by EP-WXT, within a 10 hour observation using the 2.16-m telescope. The team did not find any uncatalogued sources within the error circle down to a limiting magnitude of 22.6.

GCN-39388 — EP250220a · Thu, 20 Feb 2025 21:48:36 GMT
The MASTER-Tunka robotic telescope in Russia observed a transient object, EP250220a, with an upper limit magnitude of 12.9 in a clear filter, 228 seconds after notice time and 49332 seconds after trigger time. The observation is ongoing and the coordinates are (07h 33m 25.59s, +40d 01m 57.1s).

GCN-39387 — EP250220a · Thu, 20 Feb 2025 21:17:51 GMT
The Einstein Probe team has detected a fast X-ray transient, EP250220a, using EP-WXT. The source, located at R.A. = 113.400 deg, DEC = 39.795 deg, emitted X-rays for approximately 150 seconds starting at 2025-02-20T02:11:59 (UTC). The unabsorbed average 0.5-4 keV flux is estimated to be 5.8 (-2.2/+3.3) x 10^-11 erg/s/cm^2.

View live event on Starithm

Rendered Mon, 16 Nov 2026 07:07:06 GMT.