Starithm STARITHM NovaTrace

EP250421a

EP250421a, a X-ray transient, reported in 11 GCN Circulars. Best position RA 172.4200°, Dec -24.6757° (±2.7″) from the Swift-XRT afterglow position, GCN 40204.

Key facts

EventEP250421a
Event IDep250421a
Alert typeX-ray transient
Trigger timenot reported
Position (J2000)RA 172.4200°, Dec -24.6757° ± 2.7″ (Swift-XRT afterglow position, GCN 40204)
Fluence< 3.70e-8 erg/cm2/s (10-1000 keV, GBM, GCN 40218)
GCN notices0
GCN circulars11

Every localisation reported in Circulars (3)

InstrumentOfErrorCircular
EP-WXTburst3.0′ (90%)GCN 40198
EP-FXTafterglow10.0″ (90%)GCN 40198
Swift-XRTafterglow2.7″ (90%)GCN 40204

Burst properties (1)

From burst catalogues and as each instrument's Circular reported them; Circular values parsed from the text.

PropertyValueBandInstrumentSpectral modelSource
Fluence< 3.70e-8 erg/cm2/s10-1000 keVGBMbandGCN 40218

GCN Circulars (11)

GCN-40220 — EP250421a · Wed, 23 Apr 2025 23:13:36 GMT
The KAIT GRB team at UC Berkeley reported an upper limit of R > 20.5 (Vega) for the optical afterglow of EP250421a, using observations with the 1-m Nickel telescope at Lick observatory. No detection of the afterglow was made 14.9 hours after the trigger.

GCN-40218 — EP250421a · Wed, 23 Apr 2025 14:26:25 GMT
Fermi-GBM did not detect any signals consistent with the transient EP250421a, which was detected by EP-WXT. A flux upper limit of 3.7e-08 erg/cm2/s was derived for the energy band 10-1000 keV assuming a 'soft' spectral template.

GCN-40207 — EP250421a · Tue, 22 Apr 2025 13:46:09 GMT
Astronomers using the Nordic Optical Telescope reported the detection of a faint source at the location of the fast X-ray transient EP250421a, but were unable to confirm an optical counterpart as previously reported. The team, led by Daniele Malesani, obtained r-band and z-band observations but only detected a source with a magnitude of 23.8 +/- 0.3. The significance of this finding is that the optical counterpart, if it exists, may be very faint or non-existent.

GCN-40205 — EP250421a · Tue, 22 Apr 2025 09:22:46 GMT
The REM team at INAF-OAB reported no detection of an optical counterpart for EP250421a using the REM 60 cm robotic telescope at ESO La Silla observatory. The observation was carried out 6.9 hours after the burst and lasted for about 1 hour. The team did not detect any source down to a 3sigma limit of r > 20.6 AB.

GCN-40204 — EP250421a · Tue, 22 Apr 2025 09:04:31 GMT
The Swift/XRT team has detected an uncatalogued X-ray source, EP250421a, located approximately 35 arcsec from the position of a previously reported transient detected by EP-WXT. The X-ray source, with a mean count rate of 0.272 ct/s and signs of fading, is consistent with the X-ray and optical counterparts reported by other teams. The results are available at <https://www.swift.ac.uk/EP/EP_FIELD00035/>.

GCN-40203 — EP250421A · Tue, 22 Apr 2025 08:13:37 GMT
A team of astronomers led by Rosa L. Becerra reported an optical upper limit measurement of r > 23.44 for the counterpart of EP250421A using the DDRAGO imager on the COLIBRÍ telescope. The observation was carried out 12.6 to 13.8 hours after the trigger and lasted for 50 minutes.

GCN-40200 — EP250421a · Tue, 22 Apr 2025 05:36:49 GMT
The MASTER-OAFA robotic telescope in Argentina observed the transient event EP250421a, located at ra = '11h 29m 43.36s', dec = '-24d 18m 41.7s', with an upper limit of magnitude 20.0 in the clear filter. The observation began 2313 seconds after the notice time and 46767 seconds after the trigger time.

GCN-40198 — EP250421a · Tue, 22 Apr 2025 04:36:14 GMT
Astronomical alert: EP250421a: Einstein Probe detection of an X-ray transient

GCN-40197 — EP250421a · Tue, 22 Apr 2025 04:28:53 GMT
The Mephisto Team at Yunnan University reported the confirmation of an optical counterpart for the transient EP250421a using the 1.6m Multi-channel Photometric Survey Telescope (Mephisto). The team detected the transient in riz band images, with initial magnitudes of 20.28 ± 0.12 in i-band and 21.21 ± 0.16 in r-band. The source showed a clear decay in brightness over a short timescale.

GCN-40193 — EP250421a · Mon, 21 Apr 2025 18:54:51 GMT
Astronomers using the 100cm-C telescope at the JinShan project in China have detected an uncatalogued optical source, likely the counterpart of gamma-ray source EP250421a, which was previously detected by EP/WXT. The source is located at R.A.(J2000) = 11:29:40.80, Dec.(J2000) = -24:40:31.84, with an uncertainty of ~0.6 arcsec and a magnitude of r ~ 20.6.

GCN-40192 — EP250421a · Mon, 21 Apr 2025 18:39:24 GMT
Astronomers using the Lulin One-meter Telescope at Lulin Observatory in Taiwan have detected an optical transient, possibly associated with EP-WXT trigger 01709135179, located approximately 22.3 arcsec east and 26.8 arcsec north of the reported coordinate. The transient, named EP250421a, was observed 27 minutes after the trigger and has an initial magnitude of 21.44 +/- 0.09 in the AB system. Further observations are ongoing to identify the nature of this counterpart candidate.

View live event on Starithm

Rendered Mon, 16 Nov 2026 07:07:09 GMT.