EP250526a
EP250526a, a X-ray transient, reported in 6 GCN Circulars. Best position RA 217.0509°, Dec -34.3293° (±10.0″) from the EP-FXT afterglow position, GCN 40550. 2 measured values from follow-up observations.
Key facts
| Event | EP250526a |
|---|---|
| Event ID | ep250526a |
| Alert type | X-ray transient |
| Trigger time | not reported |
| Position (J2000) | RA 217.0509°, Dec -34.3293° ± 10.0″ (EP-FXT afterglow position, GCN 40550) |
| GCN notices | 0 |
| GCN circulars | 6 |
Every localisation reported in Circulars (2)
| Instrument | Of | Error | Circular |
|---|---|---|---|
| EP-WXT | burst | 2.9′ (90%) | GCN 40550 |
| EP-FXT | afterglow | 10.0″ (90%) | GCN 40550 |
Observations (2)
Values parsed from the Circular text; each row names its Circular.
| Time since trigger | UTC | Band | As reported | Normalised | Exposure | Telescope | Instrument | Circular |
|---|---|---|---|---|---|---|---|---|
| T+21.6 h | — | VT_B | > 23.5 mag (limit) | 23.5 AB mag | 2850 s | SVOM/VT | — | GCN 44732 |
| T+21.6 h | — | VT_R | > 23.3 mag (limit) | 23.3 AB mag | 2850 s | SVOM/VT | — | GCN 44732 |
GCN Circulars (6)
GCN-44732 — EP250526a
· Fri, 29 May 2026 02:52:08 GMT
The SVOM/VT telescope conducted observations of the field triggered by the Einstein Probe for the event EP260526a. No new sources were detected in the VT_B and VT_R channels, with 3 sigma upper limit magnitudes of >23.5 mag and >23.3 mag respectively, consistent with other observations from COLIBRÍ and LCO.
GCN-40562 — EP250526a
· Wed, 28 May 2025 12:59:03 GMT
The SVOM/VT team reported no uncatalogued source detection in follow-up observations of EP250526a, with a 3 sigma upper limit of VT_R~23.0 mag (AB) in 16*70 sec stacked images at a mid-observation time of 7.81 hours. This result is consistent with previous reports.
GCN-40554 — EP250526a
· Tue, 27 May 2025 12:44:31 GMT
The Einstein Probe mission detected an X-ray transient, EP250526a, on May 26, 2025. The event lasted approximately 175 seconds and had a peak flux of 4 x 10^-9 erg/s/cm^2. Refined analysis of the WXT data revealed an absorbed power-law spectrum with a photon index of 1.31. The FXT observed the source autonomously and found an absorbed power-law spectrum with a photon index of 2.59 for the first observation and 2.37 for the second. The unabsorbed fluxes for the FXT observations were 7.0 x 10^-13 erg/s/cm^2 and 1.2 x 10^-13 erg/s/cm^2, respectively.
GCN-40552 — EP250526a
· Tue, 27 May 2025 08:15:01 GMT
A team of astronomers led by Camila Angulo (UNAM) and Benjamin Schneider (LAM) used the DDRAGO imager on the COLIBRÍ telescope to search for a new source at the position of EP250526a. They did not detect any new source down to the following 3-sigma limits: g > 23.6, r > 23.4, i > 23.0.
GCN-40551 — EP250526a
· Tue, 27 May 2025 07:36:46 GMT
On May 27, 2025 at 07:21:21 UT, the MASTER-OAFA robotic telescope in Argentina observed a transient object, EP250526a, with an upper limit magnitude of 18.6 in the clear filter. The observation took place 15,422 seconds after the notice time and 42,778 seconds after the trigger time.
GCN-40550 — EP250526a
· Tue, 27 May 2025 03:02:34 GMT
The Einstein Probe mission detected a fast X-ray transient, EP250526a, using its Wide-field X-ray Telescope (WXT). The transient's position was determined to be R.A. = 217.049 deg, DEC = -34.355 deg (J2000) with an uncertainty of 2.9 arcmin. A follow-up observation with the Follow-up X-ray Telescope (FXT) identified an uncatalogued X-ray source at R.A. = 217.0509 deg, DEC = -34.3293 deg (J2000) with an uncertainty of 10 arcsec. Further information will be provided once telemetry data is received.
Rendered Mon, 16 Nov 2026 07:07:17 GMT.