Starithm STARITHM NovaTrace

EP250806a

EP250806a, a X-ray transient, reported in 10 GCN Circulars. Best position RA 335.1046°, Dec -26.8759° (±20.0″) from the EP-FXT afterglow position, GCN 41246.

Key facts

EventEP250806a
Event IDep250806a
Alert typeX-ray transient
Trigger timenot reported
Position (J2000)RA 335.1046°, Dec -26.8759° ± 20.0″ (EP-FXT afterglow position, GCN 41246)
T9050 s (WXT, GCN 41256)
GCN notices0
GCN circulars10

Every localisation reported in Circulars (3)

InstrumentOfErrorCircular
EP-WXTburst3.0′ (90%)GCN 41246
EP-FXTafterglow20.0″ (90%)GCN 41246
EP-FXTafterglow10.0″ (90%)GCN 41256

Burst properties (3)

From burst catalogues and as each instrument's Circular reported them; Circular values parsed from the text.

PropertyValueBandInstrumentSpectral modelSource
Duration50 s—WXTpower_lawGCN 41256
Photon index2.30.5-4 keVWXTpower_lawGCN 41256
Photon index3.240.5-10 keVFXTpower_lawGCN 41256

GCN Circulars (10)

GCN-41273 — EP250806a · Thu, 07 Aug 2025 20:05:54 GMT
Fermi-GBM did not detect a gamma-ray signal from EP250806a, a transient detected by EP-WXT. A flux upper limit of 3.7e-08 erg/cm2/s was derived for the energy band 10-1000 keV, assuming a 'soft' spectral template.

GCN-41266 — EP250806a · Thu, 07 Aug 2025 14:41:19 GMT
The SVOM team reported that the candidate source identified in a previous alert was actually a cataloged source, and no new candidates were found within the error box in VT images. The limit on the magnitude of the candidate was about VT_B~23.6 mag and VT_R~23.1 mag, 8.19 hours after the EP/WXT trigger. The results were consistent with previous reports.

GCN-41263 — EP250806a · Thu, 07 Aug 2025 11:08:34 GMT
A team of astronomers led by Amit Kumar at Royal Holloway - UoL and UCAS used the IO:O Imager at the 2m Liverpool telescope to search for the optical counterpart of the X-ray transient EP250806a. They did not detect any source at the location of the SVOM/VT optical candidate down to a limiting magnitude of >22.5 (AB).

GCN-41259 — EP250806a · Thu, 07 Aug 2025 09:00:17 GMT
The Swift-XRT team reported no X-ray sources detected in follow-up observations of Einstein Probe/WXT-detected source EP250806a. They collected 1.5 ks of PC mode data between 11-13 ks after the trigger.

GCN-41258 — EP250806a · Thu, 07 Aug 2025 08:54:20 GMT
The MASTER-SAAO robotic telescope in South Africa observed EP250806a, a transient event, with upper limits of 17.4 and 17.5 magnitudes in clear filter, 32371 seconds after notice time and trigger time. The observation took place at a zenith distance of 72 degrees and sun altitude of -28.1 degrees.

GCN-41256 — EP250806a · Thu, 07 Aug 2025 04:42:31 GMT
The X-ray transient EP250806a was detected by the Einstein Probe mission, with the Wide-field X-ray Telescope (WXT) observing a 50-second event on 2025-08-06. The Follow-up X-ray Telescope (FXT) confirmed the source position and provided additional spectral data, indicating an absorbed power law spectrum with a photon index of 3.24.

GCN-41255 — EP250806a · Thu, 07 Aug 2025 03:11:09 GMT
Astronomers using the COLIBRÍ observatory at the Observatorio Astronómico Nacional in Mexico reported the detection of a source with a magnitude of 22.47 in the optical band for the X-ray transient EP250806a, which is similar to the magnitude reported by Xin et al. but different from the one reported in a previous observation. The source was also detected in the Legacy Survey DR10 catalog with a magnitude of 22.0. The team suggests that this may not be the optical counterpart of the EP transient due to the lack of fading between observations and the resolved appearance of the source.

GCN-41254 — EP250806a · Thu, 07 Aug 2025 01:45:11 GMT
The Space Variable Objects Monitor (SVOM) performed a Target of Opportunity observation of an uncatalogued optical source, EP250806a, detected by EP/WXT. The source was detected in VT_B and VT_R channels, with magnitudes of 23.3 and 22.6 respectively, 8.19 hours after the EP trigger time. The source is located at RA: 22:20:24.76, Dec: -26:52:39.38.

GCN-41248 — EP250806a · Wed, 06 Aug 2025 14:02:40 GMT
A team of international astronomers led by Francis Fortin (IRAP) used the COLIBRÍ telescope to observe the X-ray transient EP250806a and did not detect any new source at its position down to a 3-sigma limit of i > 23.38. The observation took place 1.1 to 1.9 hours after the trigger.

GCN-41246 — EP250806a · Wed, 06 Aug 2025 10:21:46 GMT
The Einstein Probe mission has detected an X-ray transient, EP250806a, using its Wide-field X-ray Telescope (WXT). The transient's position was determined to be R.A. = 335.100 deg, DEC = -26.886 deg (J2000) with an uncertainty of 3 arcmin. A follow-up observation with the Follow-up X-ray Telescope (FXT) identified an uncatalogued X-ray source at R.A. = 335.1046 deg, DEC = -26.8759 deg (J2000) with an uncertainty of 20 arcsec. The Einstein Probe, launched in 2024, is an X-ray observatory with follow-up capabilities.