EP250807a
EP250807a, a X-ray transient, reported in 5 GCN Circulars. Best position RA 281.3110°, Dec +14.3830° (±3.0′) from the EP-WXT position, GCN 41277. 1 measured values from follow-up observations.
Key facts
| Event | EP250807a |
|---|---|
| Event ID | ep250807a |
| Alert type | X-ray transient |
| Trigger time | not reported |
| Position (J2000) | RA 281.3110°, Dec +14.3830° ± 3.0′ (EP-WXT position, GCN 41277) |
| T90 | 250 s (EP-WXT, GCN 41277) |
| Peak flux | 2.08e-8 ergs/s/cm^2 (EP-WXT, GCN 41277) |
| GCN notices | 0 |
| GCN circulars | 5 |
Every localisation reported in Circulars (1)
| Instrument | Of | Error | Circular |
|---|---|---|---|
| EP-WXT | burst | 3.0′ (90%) | GCN 41277 |
Burst properties (3)
From burst catalogues and as each instrument's Circular reported them; Circular values parsed from the text.
| Property | Value | Band | Instrument | Spectral model | Source |
|---|---|---|---|---|---|
| Duration | 250 s | — | EP-WXT | — | GCN 41277 |
| Peak flux | 2.08 1e-8 ergs/s/cm^2 | — | EP-WXT | — | GCN 41277 |
| Photon index | 1.99 | — | EP-WXT | power_law | GCN 41277 |
Observations (1)
Values parsed from the Circular text; each row names its Circular.
| Time since trigger | UTC | Band | As reported | Normalised | Exposure | Telescope | Instrument | Circular |
|---|---|---|---|---|---|---|---|---|
| T+5.1 h | — | i | > 21.67 AB mag (limit) | 21.67 AB mag | 960 s | COLIBRÍ | DDRAGO | GCN 41275 |
GCN Circulars (5)
GCN-41311 — EP250807a
· Sun, 10 Aug 2025 04:22:40 GMT
EP-FXT conducted a follow-up observation of EP250807a, no significant X-ray source was detected, and the flux upper limit was determined to be 7.4e-14 erg/cm^2/s in the 0.5-10 keV energy range.
GCN-41308 — EP250807a
· Sat, 09 Aug 2025 21:49:54 GMT
The MASTER-Kislovodsk robotic telescope in Russia conducted observations of the EP250807a event starting at twilight on August 8, 2025, with an upper limit of magnitude 17.1 in clear filter. The observations were carried out by a collaborative effort of multiple institutions and observatories including Moscow State University and the Instituto de Astrofisica de Canarias.
GCN-41286 — EP250807a
· Fri, 08 Aug 2025 12:10:28 GMT
A team of astronomers led by Radboud University observed the field of EP250807a using the ESO NTT in Chile and did not detect any new sources within the uncertainty region, setting an upper limit of z > 20.4 (AB system) for the brightest magnitude in the z band. No variability was found in the preliminary image subtraction, but further observations are planned.
GCN-41277 — EP250807a
· Fri, 08 Aug 2025 07:28:10 GMT
The Einstein Probe (EP) mission detected a fast X-ray transient, designated EP250807a, on August 7, 2025. The transient had a duration of about 250 seconds and a peak flux of 2.08 x 10^-8 ergs/s/cm^2, with follow-up observations scheduled to further investigate the event.
GCN-41275 — EP250807a
· Fri, 08 Aug 2025 06:07:18 GMT
The COLIBRÍ telescope observed the field of the EP X-ray transient EP250807a but did not detect any new optical source down to a 5-sigma limit of i > 21.67. This non-detection provides an upper limit on the optical brightness of the transient.