EP260126a
EP260126a, a X-ray transient, reported in 10 GCN Circulars. Best position RA 103.7551°, Dec +37.7053° (±10.0″) from the EP-FXT afterglow position, GCN 43526. 16 measured values from follow-up observations.
Key facts
| Event | EP260126a |
|---|---|
| Event ID | ep260126a |
| Alert type | X-ray transient |
| Trigger time | not reported |
| Position (J2000) | RA 103.7551°, Dec +37.7053° ± 10.0″ (EP-FXT afterglow position, GCN 43526) |
| T90 | 1400 s (WXT, GCN 43520) |
| Peak flux | 1.49e-9 erg/s/cm^2 (0.5-4 keV, WXT, GCN 43520) |
| GCN notices | 0 |
| GCN circulars | 10 |
Every localisation reported in Circulars (3)
| Instrument | Of | Error | Circular |
|---|---|---|---|
| EP-WXT | burst | 2.1′ (90%) | GCN 43520 |
| EP-FXT | afterglow | 20.0″ (90%) | GCN 43520 |
| EP-FXT | afterglow | 10.0″ (90%) | GCN 43526 |
Burst properties (3)
From burst catalogues and as each instrument's Circular reported them; Circular values parsed from the text.
| Property | Value | Band | Instrument | Spectral model | Source |
|---|---|---|---|---|---|
| Duration | 1400 s | — | WXT | — | GCN 43520 |
| Peak flux | 1.49 1e-9 erg/s/cm^2 | 0.5-4 keV | WXT | — | GCN 43520 |
| Photon index | 1.16 | 0.5-4 keV | WXT | — | GCN 43520 |
Observations (16)
Values parsed from the Circular text; each row names its Circular.
| Time since trigger | UTC | Band | As reported | Normalised | Exposure | Telescope | Instrument | Circular |
|---|---|---|---|---|---|---|---|---|
| T+9.5 h | — | r | > 21 AB mag (limit) | 21 AB mag | 1800 s | SLT | — | GCN 43525 |
| T+10.1 h | — | i | > 20.3 AB mag (limit) | 20.3 AB mag | 900 s | SLT | — | GCN 43525 |
| T+13.9 h | — | VT_B | > 23.4 mag (limit) | 23.4 AB mag | 2030 s | SVOM | VT | GCN 43551 |
| T+13.9 h | — | VT_R | > 22.9 mag (limit) | 22.9 AB mag | 2030 s | SVOM | VT | GCN 43551 |
| T+17.8 h | — | Sloan r | > 23.6 mag (limit) | 23.6 AB mag | — | 2.56-m Nordic Optical Telescope (NOT) | ALFOSC | GCN 43521 |
| T+17.8 h | — | Sloan z | > 22.5 mag (limit) | 22.5 AB mag | — | 2.56-m Nordic Optical Telescope (NOT) | ALFOSC | GCN 43521 |
| T+18.7 h | — | r | > 24.3 AB mag (limit) | 24.3 AB mag | — | Nordic Optical Telescope (NOT) | ALFOSC | GCN 43523 |
| T+18.7 h | — | z | > 23.2 AB mag (limit) | 23.2 AB mag | — | Nordic Optical Telescope (NOT) | ALFOSC | GCN 43523 |
| T+19.1 h | — | 0.5-10 keV | 5.65 1e-13 erg/s/cm^2 | 5.65e-13 erg/cm2/s | 20880 s | EP-FXT | FXT | GCN 43526 |
| T+19.4 h | — | i' | > 23.3 mag (limit) | 23.3 AB mag | 900 s | Liverpool Telescope | IO:O | GCN 43524 |
| T+19.4 h | — | g' | > 23 mag (limit) | 23 AB mag | 900 s | Liverpool Telescope | IO:O | GCN 43524 |
| T+21.9 h | — | r | > 24 AB mag (limit) | 24 AB mag | 4740 s | COLIBRÍ | DDRAGO | GCN 43522 |
| T+21.9 h | — | z | > 23.1 AB mag (limit) | 23.1 AB mag | 4740 s | COLIBRÍ | DDRAGO | GCN 43522 |
| — | — | g | > 21.74 AB mag (limit) | 21.74 AB mag | 1860 s | Seimei Telescope | Tricolor CMOS Camera and Spectrograph (TriCCS) | GCN 43541 |
| — | — | r | > 21.36 AB mag (limit) | 21.36 AB mag | 1860 s | Seimei Telescope | Tricolor CMOS Camera and Spectrograph (TriCCS) | GCN 43541 |
| — | — | i | > 21.33 AB mag (limit) | 21.33 AB mag | 1860 s | Seimei Telescope | Tricolor CMOS Camera and Spectrograph (TriCCS) | GCN 43541 |
GCN Circulars (10)
GCN-43832 — EP260126a
· Wed, 25 Feb 2026 15:06:53 GMT
Astronomers using the Very Large Array detected a significant rebrightening of a radio source at RA 06:55:01.01, Dec +37:42:18.68, located within the localization of an Einstein Probe event. The source, proposed as the radio counterpart of EP260126A, was observed at 6 GHz with a bandwidth of 4 GHz on January 29, 2026, and February 19, 2026. The putative host galaxy of the transient is a faint object with a magnitude of r~24 AB mag, as seen in Legacy Survey DR10 images.
GCN-43551 — EP260126a
· Thu, 29 Jan 2026 07:03:18 GMT
The SVOM/VT team reports non-detection of EP260126a in optical bands during a ToO observation, setting 3 sigma upper limits of >23.4 mag in VT_B and >22.9 mag in VT_R. This result is consistent with earlier reports from other telescopes.
GCN-43541 — EP260126a
· Wed, 28 Jan 2026 14:52:16 GMT
Astronomers using the 3.8-m Seimei Telescope at Okayama Observatory of Kyoto University conducted observations of the field of EP260126a, a transient event detected by the Einstein Probe. They took 31-minute long exposures in g, r, and i-bands and did not detect any transient sources within the error circle. The team reports 5-sigma limiting magnitudes of 21.74, 21.36, and 21.33 AB mag for g, r, and i-band, respectively.
GCN-43526 — EP260126a
· Tue, 27 Jan 2026 13:40:40 GMT
The EP-FXT telescope performed a follow-up observation of an uncatalogued X-ray source, EP260126a, detected by EP-WXT. The new observation confirmed the source's position and estimated its X-ray flux and photon index. The discovery is significant as it adds to the growing catalog of X-ray sources and may lead to further multi-band follow-up observations.
GCN-43525 — EP260126a
· Tue, 27 Jan 2026 12:48:50 GMT
Astronomers using the 40cm SLT at Lulin Observatory in Taiwan as part of the Kinder collaboration did not detect the fast X-ray transient EP260126a in optical observations in r-band and i-band. The non-detections are consistent with previous reports. The presented upper limits on magnitudes are not corrected for Galactic foreground extinction.
GCN-43524 — EP260126a
· Tue, 27 Jan 2026 09:58:21 GMT
The Liverpool Telescope on La Palma did not detect any new optical sources in the field of EP260126a, a transient event first detected by X-rays, using the IO:O instrument and SDSS i’ and g’ filters. The team obtained 6 exposures, each with a duration of 150 seconds, 19.4 hours after the X-ray detection. The derived 3-sigma upper limits for the magnitudes in i’ and g’ bands are 23.3 and 23.0, respectively.
GCN-43523 — EP260126a
· Tue, 27 Jan 2026 09:56:26 GMT
A team of astronomers led by R. A. J. Eyles-Ferris from the University of Leicester and Radboud University reported non-detection of a new source in the field of the fast X-ray transient EP260126a using the Nordic Optical Telescope (NOT) equipped with the ALFOSC camera in the SDSS r and z bands. The team obtained 3-sigma upper limits of r > 24.3 and z > 23.2 in AB magnitudes, which are consistent with previous non-detection reports. This non-detection is significant as it adds to the growing evidence that EP260126a may not have an associated optical counterpart.
GCN-43522 — EP260126a
· Tue, 27 Jan 2026 04:44:01 GMT
A team of astronomers using the COLIBRÍ telescope and DDRAGO imager did not detect any new source within the uncertainty region of EP 260126a down to the 5-sigma limits of r > 24.0 and z > 23.1.
GCN-43521 — EP260126a
· Tue, 27 Jan 2026 04:35:07 GMT
A team of astronomers led by Z.P. Zhu et al. reported non-detection of a new optical source in the field of EP260126a using the 2.56-m Nordic Optical Telescope. No source was detected down to 5-sigma upper limits of r ~ 23.6 and z ~ 22.5.
GCN-43520 — EP260126a
· Tue, 27 Jan 2026 02:36:26 GMT
The Einstein Probe mission has detected a fast X-ray transient, EP260126a, using its Wide-field X-ray Telescope. The event occurred on January 26, 2026, and lasted for approximately 1400 seconds. The source is located at R.A. = 103.737 deg, DEC = 37.699 deg (J2000), with an uncertainty of 2.1 arcmin. The average unabsorbed 0.5-4 keV flux is 2.77 (-0.26/+0.29) x 10^-10 erg/s/cm^2, and the peak flux in the same band reaches 1.49 (-0.14/+0.16) x 10^-9 erg/s/cm^2. A follow-up observation with the Follow-up X-ray Telescope detected an uncatalogued X-ray source within the error circle.
Rendered Mon, 16 Nov 2026 07:06:51 GMT.