Starithm STARITHM NovaTrace

GRB 241115D

GRB 241115D, a gamma-ray burst, reported in 6 GCN Circulars. Best position RA 19.4188°, Dec -17.9596° (±4.3″) from the Swift-XRT afterglow position, GCN 38251. 5 measured values from follow-up observations.

Key facts

EventGRB 241115D
Event IDgrb241115d
Alert typegamma-ray burst
Trigger timenot reported
Position (J2000)RA 19.4188°, Dec -17.9596° ± 4.3″ (Swift-XRT afterglow position, GCN 38251)
Redshiftnot reported
T90103 s (KW, GCN 38323)
Fluence1.54e-5 ± 0.0000021000000000000002 erg/cm^2 (20 keV - 10 MeV, KW, GCN 38323)
Peak flux7.10e-7 ± 1.8e-7 erg/cm^2/s (20 keV - 10 MeV, KW, GCN 38323)
Epeak121 ± 22 keV (20 keV - 10 MeV, KW, GCN 38323)
GCN notices0
GCN circulars6

Every localisation reported in Circulars (2)

InstrumentOfErrorCircular
EP-WXTburst2.6′ (90%)GCN 38239
Swift-XRTafterglow4.3″ (90%)GCN 38251

Burst properties (10)

From burst catalogues and as each instrument's Circular reported them; Circular values parsed from the text.

PropertyValueBandInstrumentSpectral modelSource
Duration103 s—KW—GCN 38323
Duration500 s—Wide-field X-ray Telescope (WXT)—GCN 38239
Fluence1.54 ± 0.21 1e-5 erg/cm^220 keV - 10 MeVKW—GCN 38323
Peak flux7.1 ± 1.8 1e-7 erg/cm^2/s20 keV - 10 MeVKW—GCN 38323
Peak flux1 1e-9 erg/s/cm^20.5-4 keVWide-field X-ray Telescope (WXT)—GCN 38239
Photon index-1.74 ± 0.1920 keV - 10 MeVKWcutoff_power_lawGCN 38323
Photon index-1.320 keV - 10 MeVKWcutoff_power_lawGCN 38323
Photon index0.560.5-4 keVWide-field X-ray Telescope (WXT)power_lawGCN 38239
Epeak102 ± 38 keV20 keV - 10 MeVKWcutoff_power_lawGCN 38323
Epeak121 ± 22 keV20 keV - 10 MeVKWcutoff_power_lawGCN 38323

Observations (5)

Values parsed from the Circular text; each row names its Circular.

Time since triggerUTCBandAs reportedNormalisedExposureTelescopeInstrumentCircular
T+12.7 h—C> 18.6 mag (limit)18.6 Vega mag60 sMASTER-SAAO—GCN 38242
T+30.7 h—r> 20.5 AB mag (limit)20.5 AB mag1800 sSLT—GCN 38254
T+31.2 h—r> 21.7 AB mag (limit)21.7 AB mag1800 sLOT—GCN 38254
——0.3-10 keV1.5 ± 0.38—1448 sSwiftXRTGCN 38251
——0.3-10 keV2.1 1e-12 erg/s/cm^22.10e-12 erg/cm2/s1448 sSwiftXRTGCN 38251

GCN Circulars (6)

GCN-38323 — GRB 241115D · Tue, 26 Nov 2024 20:45:20 GMT
The Konus-Wind team at Ioffe Institute reports the detection of a long-duration gamma-ray burst (GRB 241115D / EP 241115a) in waiting mode data, with a duration of approximately 103 seconds and a total burst fluence of 1.54(-0.21,+0.24)x10^-5 erg/cm^2. The team used Bayesian block analysis to identify a significant count rate increase in the 20-300 keV band, and found that the spectrum could be described by a power law with exponential cutoff model.

GCN-38254 — GRB 241115D · Sat, 16 Nov 2024 20:59:35 GMT
Astronomers using the 40cm SLT and 1m LOT at Lulin Observatory as part of the Kinder collaboration did not detect any new optical source within the error circle of the Swift-XRT localization for the fast X-ray transient EP241115a/GRB 241115D. They report 3-sigma upper limits of >20.5 mag for the SLT and >21.7 mag for the LOT observations.

GCN-38251 — GRB 241115D · Sat, 16 Nov 2024 17:37:06 GMT
The Einstein Probe team reported the detection of a new X-ray transient, EP241115a, by the Wide-field X-ray Telescope on board the Einstein Probe mission. The team performed a follow-up observation with Swift XRT, detecting an uncatalogued X-ray source consistent with the position of EP241115a. The source was fitted with an absorbed power law spectrum, and the derived average unabsorbed 0.3-10 keV flux was 2.1(+0.9/-0.5) x 10^(-12) erg/s/cm^2.

GCN-38250 — GRB 241115D · Sat, 16 Nov 2024 15:16:30 GMT
During the commissioning phase of the China-France joint mission SVOM, the gamma-ray monitor (GRM) detected a gamma-ray burst (GRB 241115D) with a duration of 45 +3/-4 seconds and multiple pulses. The burst occurred approximately 60 degrees from the optical axis and outside the field of view of another SVOM instrument. The GRM light curve was quickly downlinked to the ground and can be found online.

GCN-38242 — EP241115a · Sat, 16 Nov 2024 00:06:32 GMT
An astronomical alert was issued regarding the observation of a transient object, EP241115a, using the MASTER-SAAO robotic telescope located at the South African Astronomical Observatory. The observation began approximately 8625 seconds after the notice time and 45587 seconds after the trigger time, with an upper limit magnitude of 18.6 in the clear filter. The object's coordinates were recorded as RA: 01h 16m 06.64s, Dec: -18d 19m 58.1s, with a galactic latitude of b: -78 and longitude of l: 159.

GCN-38239 — EP241115a · Fri, 15 Nov 2024 21:32:42 GMT
The Einstein Probe team reported the detection of a fast X-ray transient, EP241115a, using the Wide-field X-ray Telescope on board the Einstein Probe mission. The transient was located at R.A. = 19.416 deg, DEC = -17.954 deg, with a peak flux of ~1 x 10^-9 erg/s/cm^2 and an average unabsorbed flux of 1.42(+0.6/-0.4) x 10^-10 erg/s/cm^2. No previously known bright X-ray sources were found within the error circle, and follow-up observations are encouraged to identify its nature.