GRB 241117A
GRB 241117A, a gamma-ray burst, reported in 7 GCN Circulars. Best position RA 2.0000°, Dec +16.3000° (±1.70°) from the Fermi-GBM position, GCN 38258. 1 measured values from follow-up observations.
Key facts
| Event | GRB 241117A |
|---|---|
| Event ID | grb241117a |
| Alert type | gamma-ray burst |
| Trigger time | not reported |
| Position (J2000) | RA 2.0000°, Dec +16.3000° ± 1.70° (Fermi-GBM position, GCN 38258) |
| Redshift | not reported |
| T90 | 8.896 ± 0.579545 s (50-300 keV, GBM catalogue) |
| Fluence | 8.87e-6 ± 4.1767e-8 erg/cm2 (10-1000 keV, GBM catalogue) |
| Peak flux | 13.206 ± 0.258632 ph/cm2/s (10-1000 keV, GBM catalogue) |
| Epeak | 733 keV (20 keV - 16 MeV, GCN 38304) |
| GCN notices | 0 |
| GCN circulars | 7 |
Every localisation reported in Circulars (2)
| Instrument | Of | Error | Circular |
|---|---|---|---|
| Fermi-GBM | burst | 1.70° (1-sigma statistical) | GCN 38258 |
| Fermi-GBM | burst | 1.74° (1-sigma statistical) | GCN 38265 |
Burst properties (18)
From burst catalogues and as each instrument's Circular reported them; Circular values parsed from the text.
| Property | Value | Band | Instrument | Spectral model | Source |
|---|---|---|---|---|---|
| Duration | 8.896 ± 0.579545 s | 50-300 keV | GBM | — | GBM catalogue |
| Fluence | 8.87e-6 ± 4.1767e-8 erg/cm2 | 10-1000 keV | GBM | — | GBM catalogue |
| Peak flux | 13.206 ± 0.258632 ph/cm2/s | 10-1000 keV | GBM | — | GBM catalogue |
| Duration | 3.2 s | — | GRM | — | GCN 38266 |
| Duration | 70 s | — | GRM | — | GCN 38266 |
| Duration | 8.9 ± 0 s | 50-300 keV | GBM | cutoff_power_law | GCN 38265 |
| Fluence | 1.24 1e-5 erg/cm2 | 20 keV - 10 MeV | — | band | GCN 38304 |
| Fluence | 9.7 ± 0.2 1e-06 erg/cm^2 | 10-1000 keV | GBM | cutoff_power_law | GCN 38265 |
| Peak flux | 1.72 1e-5 erg/cm2/s | 20 keV - 10 MeV | — | band | GCN 38304 |
| Peak flux | 13.2 ± 0.3 ph/s/cm^2 | 10-1000 keV | GBM | cutoff_power_law | GCN 38265 |
| Photon index | -0.39 | 20 keV - 16 MeV | — | band | GCN 38304 |
| Photon index | -3.54 | 20 keV - 16 MeV | — | band | GCN 38304 |
| Photon index | -0.46 ± 0.07 | — | GBM | cutoff_power_law | GCN 38265 |
| Photon index | -0.45 ± 0.07 | — | GBM | band | GCN 38265 |
| Photon index | < -3.16 ± 0.98 | — | GBM | band | GCN 38265 |
| Epeak | 733 keV | 20 keV - 16 MeV | — | band | GCN 38304 |
| Epeak | 724 ± 62 keV | — | GBM | cutoff_power_law | GCN 38265 |
| Epeak | 708 ± 68 keV | — | GBM | band | GCN 38265 |
Observations (1)
Values parsed from the Circular text; each row names its Circular.
| Time since trigger | UTC | Band | As reported | Normalised | Exposure | Telescope | Instrument | Circular |
|---|---|---|---|---|---|---|---|---|
| T+3 min | — | clear | > 19.5 mag (limit) | 19.5 Vega mag | — | MASTER-OAFA | — | GCN 38259 |
GCN Circulars (7)
GCN-38304 — GRB 241117A
· Sun, 24 Nov 2024 21:13:17 GMT
The Konus-Wind team reports the detection of a gamma-ray burst (GRB 241117A) at T0=10845.029 s UT, with an initial pulse duration of approximately 1.8 seconds and a total emission duration of around 77 seconds. The burst was observed in the energy range of 20 keV to 5 MeV, with a preliminary fluence of 1.24x10^-5 erg/cm2 and a peak flux of 1.72x10^-5 erg/cm2/s. The initial episode of the burst was best fit by the GRB (Band) model, with a low-energy photon index of -0.39 and a high-energy photon index of -3.54, and a peak energy of 733 keV.
GCN-38300 — GRB 241117A
· Fri, 22 Nov 2024 23:16:13 GMT
Astronomers from various teams using Fermi, Konus-Wind, SVOM, INTEGRAL, Swift, and Mars-Odyssey have detected a long-duration gamma-ray burst (GRB 241117A) and triangulated its location to a preliminary error box with coordinates [2.489, 16.049] and dimensions 557 sq. arcmin and 1.97 deg. The Sun distance was 130 deg. This localization may be improved.
GCN-38273 — GRB 241117A
· Tue, 19 Nov 2024 08:45:06 GMT
Swift/BAT did not initially localize GRB 241117A, but the Gamma-ray Urgent Archiver for Novel Opportunities (GUANO) triggered by a Fermi notice and obtained 200 seconds of event-mode data. The NITRATES search detected the burst with a high significance, and the resulting HEALPIX Multi-Order Coverage (MOC) skymap localized the burst with a 90% credible area of 1216 deg2 and a 50% credible area of 257 deg2. The combined Fermi/GBM and NITRATES 90% credible area was smaller at 127 deg2 and 34 deg2, respectively. GUANO is a low-latency pipeline designed for targeted recovery of BAT event mode data around the times of compelling astrophysical events.
GCN-38266 — GRB 241117A
· Mon, 18 Nov 2024 08:39:57 GMT
During the commissioning phase of the Space Variable Objects Monitor (SVOM), the SVOM/GRM detected a gamma-ray burst (GRB 241117A) with a main emission duration of about 3.2 seconds and an extended emission lasting over 70 seconds. This burst, located about 72 degrees from the SVOM optical axis, was also observed by Fermi/GBM. The SVOM is a China-France joint mission dedicated to observing transient phenomena in the energetic universe.
GCN-38265 — GRB 241117A
· Mon, 18 Nov 2024 02:17:14 GMT
Astronomical alert: GRB 241117A: Fermi GBM Detection
GCN-38259 — GRB 241117A
· Sun, 17 Nov 2024 08:45:26 GMT
The MASTER-OAFA robotic telescope in Argentina began observing Fermi GRB 241117A 113 seconds after the gamma-ray burst was detected, with upper limits on magnitudes ranging from 16.9 to 19.5 in clear band. Multiple observations were made with different exposure times.
GCN-38258 — GRB 241117A
· Sun, 17 Nov 2024 08:41:11 GMT
The Fermi Gamma-ray Burst Monitor (GBM) has detected and located a long gamma-ray burst (GRB 241117A) at a calculated position of RA = 2.0, Dec = 16.3 (J2000), with a statistical uncertainty of 1.7 degrees. The angle from the Fermi Large Area Telescope (LAT) boresight is 58.0 degrees. This significant astronomical event occurred at 03:00:43 UT on November 17, 2024.
Rendered Wed, 18 Nov 2026 08:23:34 GMT.