GRB 241229A
GRB 241229A, a gamma-ray burst, reported in 9 GCN Circulars. Best position RA 192.8930°, Dec +31.8570° (±7.6′) from the SVOM-ECLAIRs position, GCN 38697. 15 measured values from follow-up observations.
Key facts
| Event | GRB 241229A |
|---|---|
| Event ID | grb241229a |
| Alert type | gamma-ray burst |
| Trigger time | not reported |
| Position (J2000) | RA 192.8930°, Dec +31.8570° ± 7.6′ (SVOM-ECLAIRs position, GCN 38697) |
| Redshift | 0.2875 (GCN 38731) |
| T90 | not reported |
| Fluence | not reported |
| Peak flux | not reported |
| GCN notices | 0 |
| GCN circulars | 9 |
Every localisation reported in Circulars (1)
| Instrument | Of | Error | Circular |
|---|---|---|---|
| SVOM-ECLAIRs | burst | 7.6′ (90%) | GCN 38697 |
Observations (15)
Values parsed from the Circular text; each row names its Circular.
| Time since trigger | UTC | Band | As reported | Normalised | Exposure | Telescope | Instrument | Circular |
|---|---|---|---|---|---|---|---|---|
| T+84 min | — | VT_B | > 21.8 AB mag (limit) | 21.8 AB mag | 100 s | SVOM | VT | GCN 38824 |
| T+84 min | — | VT_R | > 21.8 AB mag (limit) | 21.8 AB mag | 100 s | SVOM | VT | GCN 38824 |
| T+3.6 h | — | GOTO L | > 19.6 AB mag (limit) | 19.6 AB mag | 135 s | GOTO-North | — | GCN 38705 |
| T+10.9 h | — | VT_B | > 23.2 AB mag (limit) | 23.2 AB mag | 1980 s | SVOM | VT | GCN 38824 |
| T+10.9 h | — | VT_R | > 22.5 AB mag (limit) | 22.5 AB mag | 960 s | SVOM | VT | GCN 38824 |
| T+14.1 h | — | 0.5-10 keV | 6.82 1e-14 erg/s/cm^2 | 6.82e-14 erg/cm2/s | 3000 s | Einstein Probe | FXT | GCN 38726 |
| T+14.1 h | — | 0.5-10 keV | 7.73 1e-13 erg/s/cm^2 | 7.73e-13 erg/cm2/s | 3000 s | Einstein Probe | FXT | GCN 38726 |
| T+14.1 h | — | 0.5-10 keV | 9.25 1e-14 erg/s/cm^2 | 9.25e-14 erg/cm2/s | 3000 s | Einstein Probe | FXT | GCN 38726 |
| T+18.2 h | — | — | 0.017 ± 0.0038 ct s^-1 | 0.017 counts/s | 1.9 s | Swift | XRT | GCN 38728 |
| T+18.2 h | — | 0.3-10 keV | 4.32 ± 0.96 1e-13 erg cm^-2 s^-1 | 4.32e-13 erg/cm2/s | 1.9 s | Swift | XRT | GCN 38728 |
| T+23.9 h | — | Rc | > 22.3 mag (limit) | 22.3 Vega mag | 1800 s | 1-m telescope of SAO RAS | Zeiss-1000 equipped with the CCD-photometer | GCN 38731 |
| T+33.4 h | — | 0.5-10 keV | 4.19 1e-13 erg/s/cm2 | 4.19e-13 erg/cm2/s | 2212 s | EP | FXT | GCN 38740 |
| T+40.1 h | — | 0.5-10 keV | 3.5 1e-13 erg/s/cm2 | 3.50e-13 erg/cm2/s | 4898 s | EP | FXT | GCN 38740 |
| T+2.9 d | — | R | > 21.4 mag (limit) | 21.4 Vega mag | 7200 s | 1.3m Devasthal Fast Optical Telescope (DFOT) | — | GCN 38817 |
| — | — | 0.5-10 keV | 7.94 1e-13 erg/s/cm2 | 7.94e-13 erg/cm2/s | 2828 s | EP | FXT | GCN 38740 |
GCN Circulars (9)
GCN-38824 — GRB 241229A
· Sun, 05 Jan 2025 20:37:00 GMT
The SVOM team reported no detection of a new source within the errorbox of Swift/XRT and Einstein Probe/FXT for GRB 241229A in the optical bands. They obtained 3 sigma upper limits in AB magnitude for SVOM/VT in VT_B and VT_R channels: 21.8 mag (100 sec exposure, 1.4 hours after the burst) and 21.8 mag (100 sec exposure, 1.4 hours after the burst) for the first observation, and 23.2 mag (1980 sec exposure, 10.9 hours after the burst) and 22.5 mag (960 sec exposure, 10.9 hours after the burst) for the second observation.
GCN-38817 — GRB 241229A
· Sat, 04 Jan 2025 11:21:44 GMT
The ARIES team reported non-detection of optical emission from GRB 241229A using the 1.3m Devasthal Fast Optical Telescope (DFOT) 2.89 days after the gamma-ray burst was detected by SVOM. They obtained a 3-sigma upper limit of >21.4 mag in the R filter.
GCN-38740 — GRB 241229A
· Tue, 31 Dec 2024 15:52:37 GMT
The Einstein Probe team reported the confirmation of the X-ray afterglow of GRB 241229A using the Follow-up X-ray Telescope (FXT) on board the Einstein Probe mission. The source EPF_J125129.3+314453, which was also detected by Swift/XRT, showed a clear flux decay with a powerlaw index of approximately 0.8. The team calculated the unabsorbed 0.5-10 keV flux for three observations, with the second source showing a significant decrease, suggesting it is the afterglow of GRB 241229A.
GCN-38731 — GRB 241229A
· Mon, 30 Dec 2024 22:24:52 GMT
The SAO RAS team used the 1-m telescope at SAO RAS to observe the error circle of GRB 241229A, but did not detect any new source within the enhanced XRT position or near a nearby galaxy. They obtained 6 x 300 sec images in the Rc band and measured the galaxy's brightness as R = 20.26 +/- 0.05.
GCN-38728 — GRB 241229A
· Mon, 30 Dec 2024 20:50:30 GMT
The Swift-XRT team has observed GRB 241229A, collecting 1.9 ks of data and detecting an uncatalogued X-ray source. The source is 7.1 arc-seconds from the reported afterglow candidate and shows no definitive signs of fading, but its flux is below the RASS limit. The team cannot yet confirm this as the afterglow.
GCN-38726 — GRB 241229A
· Mon, 30 Dec 2024 17:11:58 GMT
The Einstein Probe (EP) mission's Follow-up X-ray Telescope (FXT) detected three uncatalogued X-ray sources within the error circle of the Swift/ECLAIRs observation of GRB 241229A. The sources, listed with their RA, DEC, and rough flux estimates, may be afterglow candidates and will be further observed by EP-FXT.
GCN-38711 — GRB 241229A
· Sun, 29 Dec 2024 23:47:48 GMT
The Swift satellite has initiated a ToO observation of GRB 241229A detected by SVOM/ECLAIRs. Automated XRT data analysis will be presented online, with any uncatalogued X-ray sources reported and potential afterglow candidates reported via GCN Circulars.
GCN-38705 — GRB 241229A
· Sun, 29 Dec 2024 15:54:12 GMT
The Gravitational-wave Optical Transient Observer (GOTO) serendipitously detected and imaged the field of GRB 241229A, a gamma-ray burst triggered by the SVOM satellite, 3.64 hours after the trigger. No new optical source was identified within a 3-sigma limiting magnitude of L > 19.6. The observation was taken using GOTO-North and consisted of three 45-second exposures in the L-band (400-700 nm).
GCN-38697 — GRB 241229A
· Sun, 29 Dec 2024 07:12:15 GMT
On December 29, 2024 at 00:04:21 UTC, the Chinese Space-based Multi-band Astronomical Telescope (SVOM) detected a long gamma-ray burst (GRB 241229A) using its Count-Rate Trigger (CRT) system. The burst was localized to a position with RA = 192.893, DEC = +31.857 (J2000) and a 90% confidence level radius of 7.6 arcmin. SVOM automatically slewed to the burst and will report data from its Gamma-Ray Module (GRM), Multi-band X-ray Telescope (MXT), and Visible and Near-infrared Telescope (VT) at a later time.
Rendered Wed, 18 Nov 2026 08:23:38 GMT.