Starithm STARITHM NovaTrace

GRB 250127A

GRB 250127A, a gamma-ray burst, reported in 8 GCN Circulars. 15 measured values from follow-up observations.

Key facts

EventGRB 250127A
Event IDgrb250127a
Alert typegamma-ray burst
Trigger timenot reported
Position (J2000)not reported
Redshiftnot reported
T90not reported
Fluencenot reported
Peak fluxnot reported
GCN notices0
GCN circulars8

Observations (15)

Values parsed from the Circular text; each row names its Circular.

Time since triggerUTCBandAs reportedNormalisedExposureTelescopeInstrumentCircular
T+3 min—VT_B> 20.6 AB mag (limit)20.6 AB mag15 sSVOMVTGCN 39047
T+3 min—VT_R> 20.3 AB mag (limit)20.3 AB mag15 sSVOMVTGCN 39047
T+32 min—Clear> 18.2 mag (limit)18.2 Vega mag2610 sK-800—GCN 39083
T+78 min—VT_B> 23.6 AB mag (limit)23.6 AB mag2300 sSVOMVTGCN 39047
T+80 min—VT_R> 23.4 AB mag (limit)23.4 AB mag2300 sSVOMVTGCN 39047
T+2.1 h—PS1-z> 17.8 AB mag (limit)17.8 AB mag360 s1-m telescope of the LCO networkSinistroGCN 39043
T+2.3 h—sdss-r> 22.1 AB mag (limit)22.1 AB mag720 s40 cm telescope of the LCO networkSCICAM QHY600GCN 39043
T+2.5 h—VT_R> 23.7 AB mag (limit)23.7 AB mag4630 sSVOMVTGCN 39047
T+2.5 h—VT_B> 23.9 AB mag (limit)23.9 AB mag4815 sSVOMVTGCN 39047
T+5.1 h——2.9 1e-3 ct s^-12.90e-3 counts/s2900 sSwiftXRTGCN 39056
T+5.1 h—0.3-10 keV3.3 1e-13 erg cm^-2 s^-13.30e-13 erg/cm2/s2900 sSwiftXRTGCN 39056
T+19.3 h—R> 23.7 mag (limit)23.7 Vega mag1680 sZTSh—GCN 39083
——0.5-10 keV< 1.93 1e-14 erg/s/cm^2 (limit)1.93e-14 erg/cm2/s17640 sEP-FXTFollow-up X-ray Telescope (FXT)GCN 39095
——0.5-10 keV1.79—2400 sEinstein ProbeFXTGCN 39053
——0.5-10 keV1.3 1e-13 erg/s/cm^21.30e-13 erg/cm2/s2400 sEinstein ProbeFXTGCN 39053

GCN Circulars (8)

GCN-39095 — GRB 250127A · Thu, 30 Jan 2025 14:38:18 GMT
A team of astronomers led by Y.-H. I. Yin reported the fading of the x-ray afterglow of GRB 250127A, which was previously detected by Swift/XRT and EP-FXT. During a second observation with EP-FXT on board the Einstein Probe mission, the x-ray source was no longer detected, and an upper limit for its flux was estimated. This confirms the identification of the afterglow and adds to the understanding of the behavior of gamma-ray bursts.

GCN-39083 — GRB 250127A · Wed, 29 Jan 2025 18:41:18 GMT
Astronomers using the 2.6-meter ZTSh telescope at Crimean Astrophysical Observatory and the 0.8-meter K-800 telescope at Terskol Observatory did not detect any new optical sources near the position of GRB 250127A, reported by Swift XRT and EP-FXT teams. Preliminary upper limits for the non-detection are 18.2 mag (Clear filter, K-800) and 23.7 mag (R filter, ZTSh).

GCN-39056 — GRB 250127A · Tue, 28 Jan 2025 21:58:52 GMT
The Swift-XRT team reports the detection of an uncatalogued X-ray source, named Source 2, within the error region of the SVOM/ECLAIRs-detected burst GRB 250127A. The source was observed for 2.9 ks and is located 138 arcsec from the SVOM/ECLAIRs position. Its count-rate and flux were measured, and it was also detected by the FXT telescope on board of Einstein Probe.

GCN-39053 — GRB 250127A · Tue, 28 Jan 2025 17:19:14 GMT
The Einstein Probe team reported the detection of an uncatalogued X-ray source, 2.38 arcmin away from the position of GRB 250127A, using the Follow-up X-ray Telescope (FXT) on board the Einstein Probe (EP) mission. The source was detected with an average unabsorbed 0.5-10 keV flux of 1.30 (-0.68/+1.44) x 10^(-13) erg/s/cm^2 and a photon index of 1.79 (-0.92/+0.92). This detection is significant as it provides valuable data for studying the afterglow of GRB 250127A.

GCN-39047 — GRB 250127A · Mon, 27 Jan 2025 21:38:37 GMT
The SVOM/VT team reported no detection of GRB 250127A within the errorboxes of Eclairs or Swift/XRT using VT_B and VT_R channels. The 3 sigma upper limits in AB magnitude were derived for various observation times and bands. These limits are consistent with the non-detection report.

GCN-39044 — GRB 250127A · Mon, 27 Jan 2025 15:43:24 GMT
Swift observatory initiated a ToO observation of GRB 250127A detected by SVOM/ECLAIRs. Automated XRT analysis will be presented online and may report uncatalogued X-ray sources or probable afterglow candidates via GCN Circulars.

GCN-39043 — GRB 250127A · Mon, 27 Jan 2025 15:28:37 GMT
A team of astronomers led by D. Turpin at CEA-Saclay observed the field of GRB 250127A using the Sinistro instrument on the 1-m telescope of the LCO network and the SCICAM QHY600 camera on the 40 cm telescope at Cerro Tololo, Chile. They did not detect any optical source inside the SVOM/ECLAIRs error region and derived preliminary upper limits for the red and z bands. The team also noted the presence of a minor planet outside the localisation error region.

GCN-39041 — GRB 250127A · Mon, 27 Jan 2025 11:47:14 GMT
The SVOM/ECLAIRs telescope detected a long gamma-ray burst, GRB 250127A, at a location with RA, Dec = 169.589, 3.346 (J2000) and a 90% confidence uncertainty of 4.8 arcminutes. The burst was detected by both the Count-Rate Trigger and Image Trigger, with the best detection having a signal-to-noise ratio of 17.45 in the 8-120 keV energy band. The SVOM team will report on subsequent observations from MXT and VT.

View live event on Starithm