Starithm STARITHM NovaTrace

GRB 250317B

GRB 250317B, a gamma-ray burst, reported in 16 GCN Circulars. 22 measured values from follow-up observations.

Key facts

EventGRB 250317B
Event IDgrb250317b
Alert typegamma-ray burst
Trigger timenot reported
Position (J2000)not reported
Redshift3.447 (tentative) (spectroscopic, GCN 39769)
T90145.67 s (Count-Rate Trigger (CRT), GCN 39753)
Fluencenot reported
Peak fluxnot reported
GCN notices0
GCN circulars16

Burst properties (2)

From burst catalogues and as each instrument's Circular reported them; Circular values parsed from the text.

PropertyValueBandInstrumentSpectral modelSource
Duration145.67 s—Count-Rate Trigger (CRT)—GCN 39753
Duration145.67 s—ECLAIRs—GCN 39752

Observations (22)

Values parsed from the Circular text; each row names its Circular.

Time since triggerUTCBandAs reportedNormalisedExposureTelescopeInstrumentCircular
T+10 min—VT_R> 21 AB mag (limit)21 AB mag—SVOM/VT—GCN 39753
T+93 min—VT_R17.48 ± 0.02 AB mag17.48 AB mag300 sSVOM/VTVTGCN 39755
T+93 min—VT_B18.89 ± 0.01 AB mag18.89 AB mag300 sSVOM/VTVTGCN 39755
T+97 min—H15.5 ± 0.3 Vega mag15.5 Vega mag—REM 60 cm robotic telescope—GCN 39764
T+2.1 h—r18.18 ± 0.03 AB mag18.18 AB mag1380 sCOLIBRÍ (SVOM/F-GFT)OGSE test camera imagerGCN 39754
T+2.4 h—VT_R17.82 ± 0.01 AB mag17.82 AB mag250 sSVOM/VTVTGCN 39755
T+2.4 h—VT_B18.97 ± 0.02 AB mag18.97 AB mag250 sSVOM/VTVTGCN 39755
T+3.0 h—r> 18 AB mag (limit)18 AB mag—REM 60 cm robotic telescope—GCN 39764
T+14.0 h—R20.88 ± 0.13 mag20.88 Vega mag3360 sAZT-33IK—GCN 39772
T+14.0 h—R> 22.8 mag (limit)22.8 Vega mag3360 sAZT-33IK—GCN 39772
T+19.0 h—clear> 20 ± 0.1 mag (limit)20 Vega mag—Leavitt Observatory RC telescope—GCN 39774
T+19.7 h—r21.87 ± 0.08 AB mag21.87 AB mag3060 sT193cmMISTRALGCN 39767
T+20.6 h—SDSS-r21.7 ± 0.1 AB mag21.7 AB mag600 sNordic Optical Telescope (NOT)ALFOSCGCN 39770
T+22.1 h—r21.72 ± 0.05 AB mag21.72 AB mag—GTCOSIRIS+GCN 39769
T+41.3 h—R> 22.9 AB mag (limit)22.9 AB mag5400 sAZT-33IK—GCN 39790
T+44.2 h—r23.5 ± 0.4 AB mag23.5 AB mag4200 sT193cmMISTRALGCN 39777
T+2.3 d—r23.95 ± 0.25 AB mag23.95 AB mag12000 sCOLIBRÍ (SVOM/F-GFT)DDRAGOGCN 39784
T+2.7 d—R> 23.3 AB mag (limit)23.3 AB mag7080 sAZT-33IK—GCN 39790
——0.3-10 keV0.19 ± 0.04 ct/s0.19 counts/s—Swift-XRTXRTGCN 39763
——0.3-10 keV3.7 ± 0.4 1e-12 erg/cm2/s3.70e-12 erg/cm2/s—Swift-XRTXRTGCN 39763
——r'19.27 ± 0.05 AB mag19.27 AB mag—LCOGT 1-m telescopeSinistro cameraGCN 39757
——VT_R> 21 AB mag (limit)21 AB mag—SVOMVTGCN 39752

GCN Circulars (16)

GCN-39790 — GRB 250317B · Thu, 20 Mar 2025 13:21:09 GMT
Astronomers from HSE, IKI, and IKI-GRB-FuN reported continued optical observations of GRB 250317B using the 1.5-meter AZT-33IK telescope at the Sayan Solar Observatory. The afterglow was not detected, with preliminary measurements of R magnitudes 22.9 and 23.3 on March 18 and 19, respectively.

GCN-39784 — GRB 250317B · Wed, 19 Mar 2025 17:09:35 GMT
A team of astronomers led by Jean-Luc Atteia (IRAP) reported the detection of the optical afterglow of GRB 250317B using the DDRAGO imager on the COLIBRÍ telescope. The team obtained 200 minutes of exposure in the r filter at a mean observing time of To+54.5h and detected the afterglow with a magnitude of r = 23.95 +/- 0.25, confirming the break of the optical light-curve previously reported. The team acknowledges excellent support from the Observatorio Astronómico Nacional.

GCN-39777 — GRB 250317B · Wed, 19 Mar 2025 08:16:18 GMT
A team of astronomers reported their observations of the optical counterpart of GRB 250317B using the T193cm telescope at Observatoire de Haute-Provence. They obtained six exposures in the r-band and detected the afterglow, which was much fainter than previous reports. The preliminary magnitude of the source was measured to be r = 23.5 ± 0.4 mag (AB).

GCN-39774 — GRB 250317B · Tue, 18 Mar 2025 20:04:16 GMT
The Leavitt Observatory in Italy reported an optical upper limit observation of GRB 250317B, which was triggered by SVOM/ECLAIRs and SVOM/MXT. No uncatalogued optical object was detected within the SVOM error circle, with a magnitude limit of >20.0 and an error of +/- 0.1.

GCN-39772 — GRB 250317B · Tue, 18 Mar 2025 15:19:56 GMT
Astronomers at HSE, IKI, and ISTP report optical observations of GRB 250317B using the 1.5-meter AZT-33IK telescope at the Sayan Solar Observatory. The optical afterglow was detected about 0.58 days after the gamma-ray burst, and preliminary photometry was obtained in the R filter. The light curve decay index is estimated to be about -1.5.

GCN-39770 — GRB 250317B · Tue, 18 Mar 2025 13:35:17 GMT
A team of astronomers led by Z.P. Zhu reported non-detection of an optical plateau phase in the afterglow of GRB 250317B using the Nordic Optical Telescope. The team obtained two 300-second exposures in the SDSS-r band 20.56 hours after the trigger, but did not detect the optical counterpart reported by previous observations. The authors encourage further observations to monitor the evolution of the optical afterglow.

GCN-39769 — GRB 250317B · Tue, 18 Mar 2025 12:43:40 GMT
A team of astronomers led by Christina Thöne at ASU-CAS reported the discovery of spectroscopic redshift z=3.44 for the afterglow of GRB 250317B using the GTC/OSIRIS+ instrument. The observations revealed at least two low-column density Lyman systems and tentative detections of various emission lines at the same redshift. Additionally, two intervening absorbers were identified at redshifts z=3.196 and 1.029.

GCN-39767 — GRB 250317B · Mon, 17 Mar 2025 23:30:24 GMT
Astronomical alert: GRB 250317B: OHP/T193 optical observations

GCN-39764 — GRB 250317B · Mon, 17 Mar 2025 15:27:41 GMT
The REM team at INAF-OAB and ESO observatory reported the detection of the NIR counterpart of GRB 250317B using the REM 60 cm robotic telescope. The counterpart was detected in the H band with a magnitude of 15.5 ± 0.3 at 1.62 hours after the trigger. The afterglow was not detected in the r band with a 3σ limit of r > 18.0 at 3.05 hours after the trigger.

GCN-39763 — GRB 250317B · Mon, 17 Mar 2025 15:05:53 GMT
The Swift-XRT team reports the detection of an uncatalogued X-ray source within the estimated error region of GRB 250317B observed by SVOM/MXT. The source, located at RA (J2000.0): 211.6427, Dec (J2000.0): +40.0796, is fading with 3.0-σ significance and has a count-rate of 0.19 (±0.04) ct s-1 and a flux of 3.7 (±0.4) ×10-12 erg cm-2 s-1. The results of the XRT analysis and position-specific upper limit calculator are available online.

GCN-39757 — GRB 250317B · Mon, 17 Mar 2025 09:34:57 GMT
Astronomers using the Las Cumbres Observatory Global Telescope network reported the detection of the fading optical afterglow of GRB 250317B, which was previously discovered by SVOM. The team obtained a 300-sec exposure in the SDSS r' filter, detecting an uncatalogued source at the position of the optical afterglow. The measured magnitude was 19.27 with an error of 0.05.

GCN-39756 — GRB 250317B · Mon, 17 Mar 2025 08:04:00 GMT
The MXT team on the Space-based multi-band astronomical Variable Objects Monitor (SVOM) has refined the X-ray afterglow position of GRB 250317B, providing new coordinates with a smaller error radius. This position is consistent with previous reports from SVOM/F-GFT and VT.

GCN-39755 — GRB250317B · Mon, 17 Mar 2025 06:48:34 GMT
Astronomical alert: GRB250317B: SVOM/VT detection of an optical candidate from VHF data

GCN-39754 — GRB 250317B · Mon, 17 Mar 2025 06:31:31 GMT
Astronomers using the OGSE test camera imager on the COLIBRÍ telescope at the Observatorio Astronómico Nacional in Mexico detected a fading optical counterpart with a magnitude of 18.18, 81 arcsec from the position of a recent gamma-ray burst (GRB) detected by SVOM/ECLAIRs. The source is not present in Legacy Survey DR10, suggesting it is the afterglow of the GRB.

GCN-39753 — GRB 250317B · Mon, 17 Mar 2025 05:29:56 GMT
On March 17, 2025, the Space-based Multi-band Astronomical Variable Objects Monitor (SVOM) detected a gamma-ray burst, GRB 250317B, using both the Count-Rate Trigger and Image Trigger systems. The burst, which had a T90 duration of approximately 145.7 seconds, was localized to a position with a 90% confidence radius of 5.75 arcmin. SVOM's MXT instrument began observing the field 148 seconds after the trigger and identified a bright, rapidly fading uncatalogued X-ray source located 48 arcseconds away from the ECLAIRs onboard position. No uncatalogued sources were detected within MXT errors using the VT instrument, and the 3 sigma limit magnitude was about VT_R~21 mag at about 10 minutes after the trigger.

GCN-39752 — GRB 250317B · Mon, 17 Mar 2025 03:38:10 GMT
The Space-based Multi-band Astronomical Variable Objects Monitor (SVOM) detected a gamma-ray burst, GRB 250317B, using both the Count-Rate Trigger and Image Trigger systems. The burst, which occurred on March 17, 2025, had a T90 duration of approximately 145.7 seconds and a signal-to-noise-ratio of 14.27. SVOM localized the burst at RA 211.665, Dec 40.056 (J2000), with a 90% confidence level radius of 5.75 arcmin. The SVOM telescopes MXT and VT began observing the field and detected a bright, rapidly fading uncatalogued X-ray source near the burst location. The significance of this event lies in the timely detection and localization of a gamma-ray burst by SVOM, which allows for further study and analysis of this transient phenomenon.

View live event on Starithm

Rendered Wed, 18 Nov 2026 08:23:46 GMT.