GRB 260925A
GRB 260925A, a gamma-ray burst, reported in 8 GCN Circulars. Best position RA 132.4567°, Dec +24.9118° (±2.3″) from the Swift-XRT afterglow position, GCN 45739. 14 measured values from follow-up observations.
Key facts
| Event | GRB 260925A |
|---|---|
| Event ID | grb260925a |
| Alert type | gamma-ray burst |
| Trigger time | not reported |
| Position (J2000) | RA 132.4567°, Dec +24.9118° ± 2.3″ (Swift-XRT afterglow position, GCN 45739) |
| Redshift | not reported |
| T90 | 35.42 s (15-350 keV, Swift GRB table) |
| Fluence | 2.40e-7 ± 6.999999999999999e-8 erg/cm2 (15-150 keV, Swift GRB table) |
| Peak flux | 0.6 ± 0.1 ph/cm2/s (15-150 keV, Swift GRB table) |
| GCN notices | 0 |
| GCN circulars | 8 |
Every localisation reported in Circulars (4)
| Instrument | Of | Error | Circular |
|---|---|---|---|
| Swift-BAT | burst | 3.0′ (90%) | GCN 45739 |
| Swift-XRT | afterglow | 2.3″ (90%) | GCN 45739 |
| Swift-XRT | afterglow | 2.6″ (90%) | GCN 45746 |
| Swift-BAT | burst | 2.5′ (90%) | GCN 45770 |
Burst properties (10)
From burst catalogues and as each instrument's Circular reported them; Circular values parsed from the text.
| Property | Value | Band | Instrument | Spectral model | Source |
|---|---|---|---|---|---|
| Duration | 35.42 s | 15-350 keV | BAT | — | Swift GRB table |
| Fluence | 2.4 ± 0.7 1e-7 erg/cm2 | 15-150 keV | BAT | — | Swift GRB table |
| Peak flux | 0.6 ± 0.1 ph/cm2/s | 15-150 keV | BAT | — | Swift GRB table |
| Photon index | 1.6 ± 0.44 | 15-150 keV | BAT | power_law | Swift GRB table |
| Duration | 35.42 ± 10.55 s | 15-350 keV | BAT | — | GCN 45770 |
| Duration | 15 s | — | BAT | — | GCN 45739 |
| Fluence | 2.4 ± 0.7 1e-07 erg/cm2 | 15-150 keV | BAT | power_law | GCN 45770 |
| Peak flux | 0.6 ± 0.1 ph/cm2/sec | 15-150 keV | BAT | power_law | GCN 45770 |
| Peak flux | 1200 counts/s | 15-350 keV | BAT | — | GCN 45739 |
| Photon index | 1.6 ± 0.44 | — | BAT | power_law | GCN 45770 |
X-ray light curve
Swift-XRT 0.3-10 keV flux light curve, 5 points: https://www.swift.ac.uk/xrt_curves/01513316/
Swift-XRT light curves from the UK Swift Science Data Centre (Evans et al. 2007, 2009).
Observations (14)
Values parsed from the Circular text; each row names its Circular.
| Time since trigger | UTC | Band | As reported | Normalised | Exposure | Telescope | Instrument | Circular |
|---|---|---|---|---|---|---|---|---|
| T+115 s | — | white_FC | > 20 mag (limit) | 20 Vega mag | 147 s | Swift | UVOT | GCN 45752 |
| T+115 s | — | white | > 20.9 mag (limit) | 20.9 Vega mag | 358 s | Swift | UVOT | GCN 45752 |
| T+5 min | — | u_FC | > 19.1 mag (limit) | 19.1 Vega mag | 246 s | Swift | UVOT | GCN 45752 |
| T+5 min | — | u | > 19.3 mag (limit) | 19.3 Vega mag | 304 s | Swift | UVOT | GCN 45752 |
| T+9 min | — | b | > 18.2 mag (limit) | 18.2 Vega mag | 62 s | Swift | UVOT | GCN 45752 |
| T+10 min | — | w2 | > 18.3 mag (limit) | 18.3 Vega mag | 39 s | Swift | UVOT | GCN 45752 |
| T+10 min | — | v | > 17.9 mag (limit) | 17.9 Vega mag | 78 s | Swift | UVOT | GCN 45752 |
| T+11 min | — | w1 | > 18.3 mag (limit) | 18.3 Vega mag | 55 s | Swift | UVOT | GCN 45752 |
| T+18 min | — | m2 | > 17.6 mag (limit) | 17.6 Vega mag | 19 s | Swift | UVOT | GCN 45752 |
| T+112 min | — | R_C | > 15.3 Vega mag (limit) | 15.3 Vega mag | 1218 s | FRAM-Auger | — | GCN 45744 |
| T+3.3 h | — | r | > 23.17 AB mag (limit) | 23.17 AB mag | 3840 s | COLIBRÍ | DDRAGO | GCN 45745 |
| T+3.3 h | — | z | > 22.46 AB mag (limit) | 22.46 AB mag | 3840 s | COLIBRÍ | DDRAGO | GCN 45745 |
| T+13.5 h | — | J | > 18.49 Vega mag (limit) | 18.49 Vega mag | — | SYSU 80cm infrared telescope | — | GCN 45756 |
| — | — | R_C | > 14 Vega mag (limit) | 14 Vega mag | 60 s | FRAM-Auger | — | GCN 45744 |
Swift data
GRB 260925A, Swift/BAT trigger 1513316: Swift GRB table · XRT position · XRT light curve · Burst analyser
GCN Circulars (8)
GCN-45770 — GRB 260925A
· Sun, 27 Sep 2026 16:43:21 GMT
The Swift-BAT team has refined the analysis of GRB 260925A, determining its precise position and characteristics. The gamma-ray burst showed a weak pulse lasting approximately 35 seconds, with a power-law spectrum and a fluence of 2.4 x 10^-07 erg/cm2 in the 15-150 keV band.
GCN-45756 — GRB 260925A
· Sat, 26 Sep 2026 09:34:57 GMT
The SYSU 80cm infrared telescope observed the field of GRB 260925A 13.5 hours after its detection, but no counterpart was found at the enhanced XRT position, with a 5-sigma upper limit of J ~ 18.49 mag (Vega). This non-detection provides constraints on the optical afterglow of the gamma-ray burst.
GCN-45755 — GRB 260925A
· Sat, 26 Sep 2026 07:34:22 GMT
The Swift-XRT team has analyzed data from GRB 260925A, finding a power-law decay in the X-ray light curve with an index of 2.95. The spectrum is best fitted with an absorbed power-law, indicating a photon spectral index of 1.6 and an absorption column consistent with the Galactic value.
GCN-45752 — GRB 260925A
· Fri, 25 Sep 2026 20:48:29 GMT
Swift/UVOT observations of GRB 260925A began 115 seconds after the BAT trigger but detected no optical afterglow. Preliminary upper limits for various filters were reported, indicating the absence of a detectable optical transient.
GCN-45746 — GRB 260925A
· Fri, 25 Sep 2026 13:43:00 GMT
The Swift-XRT team has reported an enhanced X-ray position for the gamma-ray burst GRB 260925A, with coordinates RA (J2000): 08h 49m 49.63s, Dec (J2000): +24d 54' 40.7" and an uncertainty of 2.6 arcsec. This position may be further refined as more data are received.
GCN-45745 — GRB 260925A
· Fri, 25 Sep 2026 12:59:57 GMT
The COLIBRÍ telescope observed the field of GRB 260925A and did not detect any optical source within the enhanced XRT error circle, setting 5-sigma upper limits of r > 23.17 and z > 22.46. This non-detection is significant for understanding the nature and afterglow of the gamma-ray burst.
GCN-45744 — GRB 260925A
· Fri, 25 Sep 2026 12:31:19 GMT
The FRAM-Auger telescope at the Pierre Auger Observatory responded to the Swift/BAT alert of GRB 260925A, obtaining a series of R-band images approximately 89 minutes after the trigger. No optical source was detected at the Swift/XRT enhanced position, with a limiting magnitude of R_C > 15.3.
GCN-45739 — GRB 260925A
· Fri, 25 Sep 2026 07:34:59 GMT
The Swift Burst Alert Telescope (BAT) detected a gamma-ray burst, GRB 260925A, on September 26, 2025, at 07:13:02 UT. The burst had a single-peaked structure lasting about 15 seconds, with a peak count rate of approximately 1200 counts per second. The X-ray Telescope (XRT) identified a fading X-ray source, but no credible afterglow candidate was found in the UVOT data.
Rendered Mon, 16 Nov 2026 07:06:09 GMT.