sb25061207
sb25061207 reported in 8 GCN Circulars. 2 measured values from follow-up observations.
Key facts
| Event | sb25061207 |
|---|---|
| Event ID | sb25061207 |
| Alert type | UNKNOWN |
| Trigger time | not reported |
| Position (J2000) | not reported |
| GCN notices | 0 |
| GCN circulars | 8 |
Observations (2)
Values parsed from the Circular text; each row names its Circular.
| Time since trigger | UTC | Band | As reported | Normalised | Exposure | Telescope | Instrument | Circular |
|---|---|---|---|---|---|---|---|---|
| T+9.9 h | — | r | > 22.1 AB mag (limit) | 22.1 AB mag | — | T120cm | Observatoire de Haute-Provence | GCN 40744 |
| — | — | VT_B | 21.6 ± 0.2 AB mag | 21.6 AB mag | 50 s | SVOM/VT | VT | GCN 40707 |
GCN Circulars (8)
GCN-40750 — sb25061207
· Mon, 16 Jun 2025 18:56:01 GMT
A team led by N. Pankov, A. Pozanenko, and R. Ya. Inasaridze performed optical observations of X-Ray transient sb25061207 using the 0.7-meter AS-32 telescope at AbAO. They did not detect the optical counterpart and reported a preliminary upper limit of R-band magnitude 20.0, which is consistent with other reports.
GCN-40744 — sb25061207
· Mon, 16 Jun 2025 10:28:28 GMT
A team of astronomers observed the field of the SVOM sb25061207 X-ray transient using the T120cm telescope at Observatoire de Haute-Provence, France. They did not detect the VT optical counterpart down to a 3-sigma upper limit of r > 22.1 in the r-band, 10.6 hours after the trigger.
GCN-40731 — sb25061207
· Sun, 15 Jun 2025 03:55:24 GMT
The Mephisto Team at Yunnan University reported no detection of a credible source at the position of a gamma-ray burst detected by SVOM/ECLAIRs using their Multi-channel Photometric Survey Telescope (Mephisto). They acquired three exposures of 300 seconds each in the u, v, r bands and obtained preliminary 3-sigma upper limits of >21.24, >21.31, >21.60, and >21.83 in AB magnitudes, respectively. These limits are consistent with SVOM/COLIBRÍ.
GCN-40723 — sb25061207
· Fri, 13 Jun 2025 19:16:15 GMT
A team of international researchers using the SVOM/COLIBRÍ telescope did not detect any new source at the position of a gamma-ray burst (sb25061207) down to a 3-sigma limit of r > 22.9. This observation was carried out 17.36 to 19.41 hours after the trigger and lasted for 63 minutes.
GCN-40718 — sb25061207
· Fri, 13 Jun 2025 07:28:28 GMT
The Einstein Probe team reported a follow-up observation of an uncatalogued X-ray source, EP_J131222.6+000433, detected by SVOM/VT and confirmed by Swift/XRT. The observation was carried out using the Follow-up X-ray Telescope (FXT) on board the Einstein Probe (EP) mission, which began approximately 8 hours after the detection. The estimated X-ray flux for the source was measured to be 5.4(+/-1.7) x 10^-14 erg/s/cm^2 with a signal-to-noise ratio of 5.6. The source exhibited a decreasing trend in X-ray flux between the two epochs.
GCN-40711 — sb25061207
· Thu, 12 Jun 2025 21:12:28 GMT
The Swift-XRT team reported observing and identifying four uncatalogued X-ray sources, SWIFT J131222.8+000431, SWIFT J131136.2+000123, SWIFT J131139.2-000814, and SWIFT J131140.3-000120, using Swift-XRT data from the SVOM/ECLAIRs-detected source sb25061207. The team detected significant X-ray emission from all four sources and calculated their corresponding fluxes and distances from the SVOM/ECLAIRs position.
GCN-40707 — sb25061207
· Thu, 12 Jun 2025 15:40:31 GMT
The SVOM mission detected an optical counterpart to a gamma-ray burst (sb25061207) using the SVOM/VT telescope, identifying a candidate source at RA 13:12:22.597, Dec +00:04:30.28. The source initially faded and then rebrightened to a peak magnitude of VT_R ~ 18.0 mag around 1000 seconds after the trigger, suggesting it might be a low redshift transient.
GCN-40697 — sb25061207
· Thu, 12 Jun 2025 11:30:52 GMT
The SVOM mission detected a new X-ray transient, sb25061207, using its ECLAIRs Image Trigger system on June 12, 2025. The transient was located with a 90% confidence level and had a signal-to-noise-ratio of 7.34 in the [5-20] keV energy band. The SVOM team began observing the field with MXT and VT, but no source was initially detected with MXT. The event marks a significant discovery by the Space-based multi-band astronomical Variable Objects Monitor (SVOM) dedicated to observing transient phenomena in the energetic universe.
Rendered Mon, 16 Nov 2026 07:08:06 GMT.