GRB 260704A
AI Summary
The SVOM mission detected a gamma-ray burst (GRB 260704A) with multiple peaks including a precursor and main pulse. Key measurements indicate a burst duration of T90=166+10/-7 seconds in the 4-120 keV band, possibly classifying it as an X-ray flash. Follow-up observations include detection of an uncatalogued X-ray source and a faint optical counterpart.
Key facts
| Event | GRB 260704A |
|---|---|
| Event ID | sb26070403 |
| Alert type | gamma-ray burst |
| Trigger time | 2026-07-04 03:40:24 UTC |
| Position (J2000) | RA 318.7072°, Dec -25.5102° ± 33.8″ (notice svom.voevent.mxt) |
| Redshift | not reported |
| T90 | 166 s (4-120 keV, ECLAIRs, GCN 45129) |
| Fluence | 6.1 erg/cm² (4-120 keV, ECLAIRs, GCN 45129) |
| Peak flux | not reported |
| GCN notices | 2 |
| GCN circulars | 5 |
Burst properties (5)
From burst catalogues and as each instrument's Circular reported them; Circular values parsed from the text.
| Property | Value | Band | Instrument | Spectral model | Source |
|---|---|---|---|---|---|
| Duration | 166 s | 4-120 keV | ECLAIRs | — | GCN 45129 |
| Fluence | 1.7 erg/cm² | 4-120 keV | ECLAIRs | — | GCN 45129 |
| Fluence | 6.1 erg/cm² | 4-120 keV | ECLAIRs | — | GCN 45129 |
| Photon index | -2.71 | 5-120 keV | ECLAIRs | — | GCN 45129 |
| Photon index | -1.96 | 5-120 keV | ECLAIRs | — | GCN 45129 |
Observations (6)
Values parsed from the Circular text; each row names its Circular.
| Time since trigger | UTC | Band | As reported | Normalised | Exposure | Telescope | Instrument | Circular |
|---|---|---|---|---|---|---|---|---|
| T+60 min | 2026-07-04 04:40:24 | 0.5-10 keV | 1.49 ± 0.24 erg/cm2/s | 1.49e-12 erg/cm2/s | 2600 s | EP-FXT | — | GCN 45078 |
| T+23.1 h | 2026-07-05 02:46:24 | i | > 22.5 AB mag (limit) | 22.5 AB mag | 1080 s | Nordic Optical Telescope (NOT) | ALFOSC | GCN 45083 |
| T+11.5 d | 2026-07-15 16:40:24 | r | 23.54 ± 0.22 AB mag | 23.54 AB mag | 6240 s | SVOM/COLIBRÍ (FM-GFT) | DDRAGO | GCN 45102 |
| T+11.5 d | 2026-07-15 16:40:24 | z | 22.7 ± 0.27 AB mag | 22.7 AB mag | 6240 s | SVOM/COLIBRÍ (FM-GFT) | DDRAGO | GCN 45102 |
| T+21.5 d | 2026-07-25 15:52:24 | r | 24.08 ± 0.23 AB mag | 24.08 AB mag | 6660 s | SVOM/COLIBRÍ (FM-GFT) | DDRAGO | GCN 45102 |
| T+21.5 d | 2026-07-25 15:52:24 | z | 23.19 ± 0.28 AB mag | 23.19 AB mag | 6660 s | SVOM/COLIBRÍ (FM-GFT) | DDRAGO | GCN 45102 |
Notices (1)
SVOM — GRB · Sat, 04 Jul 2026 03:43:24 GMT
GCN Circulars (5)
GCN-45129 — GRB 260704A
· Fri, 10 Jul 2026 07:41:16 GMT
The SVOM/ECLAIRs team reported a refined analysis of GRB 260704A, noting a multiple peak lightcurve with a precursor and a main pulse. The burst's refined localization and spectral analysis suggest it may be classified as an X-ray flash.
GCN-45102 — GRB 260704A
· Tue, 07 Jul 2026 13:16:54 GMT
A faint, uncatalogued source detected by the SVOM/COLIBRÍ telescope is a possible optical counterpart of the gamma-ray burst GRB 260704A, as it faded over subsequent observations. This detection in two independent optical bands suggests it could be the optical counterpart of the GRB.
GCN-45083 — GRB 260704A
· Mon, 06 Jul 2026 06:20:45 GMT
Astronomers observed the field of GRB 260704A using the Nordic Optical Telescope (NOT) but did not detect any new optical source within the error region of the X-ray source, setting an upper limit of i > 22.5. A bright star within the region was identified as not related to the X-ray source.
GCN-45078 — GRB 260704A
· Sat, 04 Jul 2026 14:56:07 GMT
The Einstein Probe (EP) performed a follow-up observation of GRB 260704A, detected by SVOM/ECLAIRs, identifying an uncatalogued X-ray source with an average unabsorbed flux of 1.49 x 10^(-12) erg/s/cm^2. This observation, conducted about an hour after the initial detection, provides crucial data for studying the afterglow of the gamma-ray burst.
GCN-45072 — GRB 260704A
· Sat, 04 Jul 2026 04:49:49 GMT
The SVOM mission detected a possible gamma-ray burst (GRB) on July 4, 2026, at 03:41:05 UTC, with a signal-to-noise ratio of 7.66 in the 5-20 keV energy band. The event was localized to RA 318.5239, Dec -25.6141 degrees with a 90% confidence radius of 10.25 arcminutes, and an uncatalogued X-ray source was subsequently identified.
AI summary generated Wed, 18 Nov 2026 03:22:06 GMT.