XRF011030
XRF011030, a X-ray transient, reported in 2 GCN Circulars. 3 measured values from follow-up observations.
Key facts
| Event | XRF011030 |
|---|---|
| Event ID | xrf011030 |
| Alert type | X-ray transient |
| Trigger time | not reported |
| Position (J2000) | not reported |
| GCN notices | 0 |
| GCN circulars | 2 |
Observations (3)
Values parsed from the Circular text; each row names its Circular.
| Time since trigger | UTC | Band | As reported | Normalised | Exposure | Telescope | Instrument | Circular |
|---|---|---|---|---|---|---|---|---|
| — | — | J | > 19.8 mag (limit) | 19.8 Vega mag | — | TIRGO | ARNICA | GCN 1145 |
| — | — | K | > 18 mag (limit) | 18 Vega mag | — | TIRGO | ARNICA | GCN 1145 |
| — | — | 2-10 keV | 2.40e-13 erg/cm2/s | 2.40e-13 erg/cm2/s | 47000 s | Chandra | — | GCN 1143 |
GCN Circulars (2)
GCN-1145 — XRF011030
· Wed, 21 Nov 2001 14:25:54 GMT
On Oct 30, 2021, the TIRGO observatory imaged the field of XRF011030 with the ARNICA camera and J and K filters. No source was detected at the position of the radio transient reported by Taylor et al. nor in the Chandra error box of the X-ray source detected by Harrison et al. The 5-sigma limiting magnitudes of J and K were 19.8 and 18.0, respectively.
GCN-1143 — XRF011030
· Sun, 18 Nov 2001 02:59:44 GMT
The Chandra Observatory detected an X-ray source within 1.2'' of a radio transient. The X-ray spectrum is consistent with a power law of photon index ~1.45, with interstellar absorption levels of N_H ~ 2e21 cm^-2.